No.
Part name
0
Under panel,
Drain pan
Procedure
1. Detachment
1) Take off the drain cap and drain the drain water
accumulated in the drain pan.
In case of natural drain model, drain the drain
water by taking off hose band and drain hose.
NOTE)
When taking off drain cap and drain hose, be
sure receive drain water in a bucket, etc.
2) Slightly loosen the screw holding the under
panel in place.
(Ø4×10 3 pcs)
3) Move the under panel toward the air intake
side to hang the panel.
4) Pull out the drain pan.
NOTE)
• When pulling out the drain pan, never pull out
the drain socket by drawing it with hands.
If doing so, water leak may be caused.
• When pulling out the drain pan, some drain
water may still be left in the pan so be
absolutely sure to discard this water.
5) After pulling out the drain pan slightly, pull it out
again toward the air intake side to detach the
pan.
2. Attachment
1) Hook the drain pan to the flange portion of the
air intake side to attach the pan, and then push
it in.
2) Hook the under panel on the screws that you
untightened in step 1-2) of "0Under panel,
Drain pan" and tighten these screws.
3) Attach the drain cap and drain hose that you
removed in step 1-1) of "0Under panel, Drain
pan." When you attach the drain cap and drain
hose, be sure to insert them firmly into the
base of the drain socket of the drain pan.
NOTE)
Finally, be sure to check there is no water
leakage from each attached part.