Toshiba RAS-M07G3DV-E Service Manual page 105

Air-conditioner multi-split type
Hide thumbs Also See for RAS-M07G3DV-E:
Table of Contents

Advertisement

FC
Item
01
Filter sign lighting time
02
Filter stain level
06
Heating suction temp. shift
10
Type
11
Indoor unit capacity
17
Cooling suction temp. shift
In automatic cooling/heating,
temp. width of cool → heat,
1E
heat → cool mode selection
control point
Automatic reset of power
28
failure
32
Sensor selection
5d
External static pressure
3. Monitor function
The sensor temperature or operational status of indoor unit, outdoor unit, or remote controller can be monitored.
Monitor function
Code
Data
00
0024
Return
Item code
01
Room temperature
(Remote controller)
02
Indoor suction temperature (TA)
03
Indoor heat exchanger (Coil)
temperature (TCJ)
04
Indoor heat exchanger (Coil)
temperature (TC)
∗ 07
Indoor fan revolution frequency
∗ F2
Indoor fan calculated operation
time
F3
Filter sign time
∗ F8
Indoor discharge temperature*1
Function selection item No. (FC) list
0000: None
0002: 2500H
0004: 10000H
0000: Standard
0001: Heavy stain (Half of standard time)
0000: No shift
0002: +2°C
0000: IMS duct
0000: Undecided
0000: No shift
0002: +2°C
0000: 0 deg
(Cool/heat are reversed with ± (Data value) /
2 against the set temperature)
0000: None
0000: Body TA
sensor
SET DATA
0000
0001
0002
0003
0004
Data name
×100h
Contents
0001: 150H
0003: 5000H
0005: Clogging sensor used
0001: +1°C
to
0010: +10°C
0001 to 0034
0001: +1°C
to
0010: +10°C
to
0010: 10 deg
0001: Provided
0001: Remote controller
sensor
External static pressure
Depends on
DIPSW 501-1,-2
10 Pa
20 Pa
35 Pa
45 Pa
1
Push the [
function" on the "Field setting menu" screen, then push
the "
Set
Push the [
data.
2
Push the [
setting menu" screen.
Unit
Item code
°C
60
°C
61
°C
62
°C
63
rpm
6A
70
72
×1h
°C
F1
– 104 –
At shipment from factory
0000: None
0000: Standard
0002: +2°C
0000: IMS duct
According to capacity type
M07: 0001 M22: 0010
M10: 0003 M24: 0011
M13: 0005
M16: 0007
0000: No shift
0003: 3 deg
(Ts±1.5)
0000: None
0000: Body sensor
0000: Depends on
DIPSW 501-1,-2
∧] / [
∨] button to select "4. Monitor
Set" [
F2] button.
∧] / [
∨] button to select the code to check
CANCEL] button to return to the "Field
Data name
Outdoor heat exchanger (Coil)
temperature (TE)
Outside temperature (TO)
Compressor discharge
temperature (TD)
Compressor suction temperature
(TS)
Operation current (× 1/10)
Compressor operation frequency
Outdoor fan revolution frequency
(Lower)
Compressor calculated operation
time
Unit
°C
°C
°C
°C
A
rps
rpm
×100h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents