4. Add myQ devices
Use an internet enabled smartphone to add devices� Follow the instruc-
tions on the app�
Note: After you add a device, the blue light on the internet gateway will
appear and stay on�
For smartphones/tablets free apps can be downloaded from iTunes
Store or Google Play�
5. Test
After having installed and registered correctly you may now test the
following features:
• open and close the garage door
• status request DOOR OPEN or DOOR CLOSED
27
Special Features
A.
Door within a door connection
To connect a door in door switch (8�2k Ohm), the ADP-1EVO
adapter is required� The instructions in the adapter manual must
be followed�
B.
Flashing light connection
Description of feature:
The flashing light can be installed anywhere. Connect light leads to
quick connect terminals 6 and 7�
C.
Partial opening feature
Description of feature:
The pedestrian , ventilation or pet opening position is an adjustable
second stop position between the fully opened and fully closed
position of the garage door�
Activate:
NOTE: Any time programming requires pushing two buttons simul-
taneously, make sure this is executed accurately� If other buttons
than described will flash, briefly cut operator from current and start
rogramming from the beginning�
1�
Move the door into to the desired partial opening position
using the remote control or wallcontrol�
2�
Choose a non programmed button on your remote control�
3�
Push square button and UP button simultaneously for 3
seconds and wait for the operator light to flash. Then push
the remote control button� To program an additional remote
control start again with step1�
Deactivate:
1�
Move the door to the fully closed position�
2�
Push square button and UP button simultaneously for 3
seconds and wait for the operator light to flash.
(optional)
D.
Instructions for Auto-Close Feature
Description of feature: The photocells must be installed (required
by EU: EN60335-2-95, GB (UK, NI) : BS EN60335-2-95)�
Activate:
Push square and DOWN button simultaneously until th eoperator
light blinks� 1 push UP button = 10 seconds� up to 180 sec� possi-
ble (18x) During countdown the down button flashes. To complete
programming push square button�
Deactivate:
Push square and DOWN button simultaneously until th eoperator
light blinks� To complete programming push square button�
Notes:
- The auto-close timer resets if the photocells are interrupted�
- In the partial open position automatic close is not possible�
- The garage door operator must have reached the programmed
UP limit to activate the auto-close timer�
Troubleshooting:
Question: Operator will not work anymore without photocells�
Solution: Correct� Photocells are mandatory once connected�
A full logic board reset is required�
E.
Change from fast speed to slow speed Description of feature:
The garage door opener chooses the necessary speed automati-
cally�
Change speed:
1� Move the door to the fully closed position�
2� Push UP and DOWN buttons simultaneously until operator light
blinks�
Attention: One piece doors, Canopy garage doors and any other
type of swing-out doors must be operated with slow speed� For
safety reasons, below 1�9m of travel length the speed is slow�
F.
OPEN, STOP or CLOSE programming of the remote control.
Description of feature:
Each remote control button can be programmed to either OPEN,
STOP or CLOSE the door�
OPEN:
Push yellow round button and UP button simultaneously until the
LED goes on� Now push a selcted button on the remote control for
OPEN only and wait for the operator light to flash.
STOP:
Push yellow round button and square button simultaneously until
the LED goes on� Now push another selcted button on the remote
control for STOP only and wait for the operator light to flash.
CLOSE:
Push yellow round button and DOWN button simultaneously until
the LED goes on� now push a third button on the remote control for
CLOSE only and wait for the operator light to flash.