15 ELECTRICAL SYSTEM
15.3
112
S03489-11
Charging the 12-V battery
Note
Environmental hazard 12 V batteries contain environmentally hazardous materials.
–
Do not dispose of 12 V batteries as household waste.
–
Dispose of 12 V batteries at a collection point for used batteries.
Note
Environmental hazard Hazardous substances cause environmental damage.
–
Dispose of oils, grease, filters, fuel, cleaning agents, brake fluid, etc., correctly and in compliance with
the applicable regulations.
Info
Even if there is no load on the 12-V battery, it discharges each day.
The charging level and the method of charging are very important for the service life of the 12-V battery.
Rapid recharging with a high charging current shortens the service life of the battery.
If the 12-V battery is depleted by repeated starting, the 12-V battery must be charged immediately.
–
bk
Connect positive cable
Guideline
Screw, battery termi-
nal
Info
A
Contact disk
must be mounted under screw
bm
cable lug
with the claws toward the battery termi-
nal.
–
Slide positive terminal cover
–
bo
Connect negative cable
Guideline
Screw, battery termi-
nal
Finishing work
–
Mount the seat. (
p. 72)
Preparatory work
–
Remove the seat. (
p. 72)
–
Remove the 12-V battery.
to the 12-V battery.
M5
2.5 Nm
(1.84 lbf ft)
bn
over the positive terminal.
to the 12-V battery.
M5
2.5 Nm
(1.84 lbf ft)
(
p. 109)
bl
and