Omron SYSMAC C200H CPU01-E Installation Manual page 145

Table of Contents

Advertisement

Programming Instructions
Name
Mnemonic
DISPLAY MESSAGE
(@)MSG(46)
LONG MESSAGE
(@)LMSG(47)
(CPU11)
TERMINAL MODE
(@)TERM(48)
(CPU11)
SET SYSTEM
(@)SYS(49)
(CPU11)
Data Areas
These footnote tables show the actual ranges of all data areas. Bit numbers are provided (except for DM and TC areas); remove the rightmost two digits for word numbers.
IR
00000 to 23515 23600 to 25507
Downloaded from
Elcodis.com
electronic components distributor
All manuals and user guides at all-guides.com
Symbol
MSG(46)
FM
LMSG(47)
S
D
–––
TERM(48)
–––
–––
–––
SYS(49)
P
–––
–––
SR
HR
TR
HR 0000 to 9915
TR 0 to 7
Function
Displays eight words of ASCII code, start-
ing from FM, on the Programming Console
or GPC. All eight words must be in the
same data area.
A
B
FM
C
D
FM+ 7
D
P
ABCD........DP
Outputs a 32-character message to either
a Programming Console, or a device con-
nected via the RS-232C interface. The
output message must be in ASCII begin-
ning at address S. The destination of the
message is designated in D: 000 specifies
that the message is to be output to the
GPC; 001 specifies the RS-232C inter-
face, starting with the leftmost byte; and
002 specifies the RS-232C interface,
starting from the rightmost byte.
When the execution condition is ON, the
Programming Console operation mode is
changed to TERMINAL mode. There is no
program command available to change the
mode back to CONSOLE mode. Pressing
the CHNG key on the Programming Con-
sole manually toggles between the two
modes.
Used to either control certain operating
parameters, or to execute the system
commands that can be executed from the
AR area.
The contents of the leftmost 8 bits (i.e., bits
08 to 15) of P determine which function
SYS(49) will have. If they contain A3, then
bit 00 specifies whether the battery will be
checked, and bit 07 specifies whether I/O
status will be maintained on start up. Bit 06
specifies whether the Force Status Hold
Bit is set.
To be effective SYS(49) must be pro-
grammed at address 00001 with LD AR
1001 at address 00000.
AR
LR
AR 0000 to 2715
LR 0000 to 6315
TC 000 to 511
Appendix E
Operand Data Areas
FM:
IR
HR
AR
LR
TC
DM
#
S:
D:
IR
#000
HR
#001
AR
#002
LR
TC
DM
None
P:
–––:
#
Not used.
TC
DM
Read/Wr: DM 0000 to DM 0999
Rd only: DM 1000 to DM 1999
–––:
Not
used.
#
0000 to 9999
or 0000 to FFFF
131