Programmable Z Divider; Pegel Conversion Z Puls (Z Divider: All Off); Setting The Z Divider - Hohner IT 210 Operating Manual

Level converter, direction signal decoder and programmable pulse divider
Table of Contents

Advertisement

6. Programmable Z Divider

6.1. Pegel conversion Z Puls (Z Divider: all OFF)

If the Z pulse have to be switched unchanged from the input to the output (no
division, no change in length and position), then the DIL switch position listed below
must be chosen.
DIL4 (right 8-pole)
1
2
3
4
OFF OFF OFF OFF OFF OFF OFF OFF
The output at the level conversion can be set to zero (ZOUT = Low) with the control
input X2(3) ZERO_Z = High.
The function is active as long as there is a high level at the control input. The Z pulse
can be trimmed by switching.

6.2. Setting the Z Divider

The programming of the Z divider is subject to the same rules as the programming of
the A/B divider.
DIL4 (right 8-pole)
1
2
3
4
ON OFF OFF OFF OFF OFF OFF OFF
OFF ON OFF OFF OFF OFF OFF OFF
ON ON OFF OFF OFF OFF OFF OFF
OFF OFF ON ON ON ON ON ON
ON OFF ON ON ON ON ON ON
OFF ON ON ON ON ON ON ON
ON ON ON ON ON ON ON ON
It210_01a_oi_e.docx / Jan-20
www.hohner-elektrotechnik.de
Divider [Z]
5
6
7
8
Divider [Z]
5
6
7
8
Comment
Binary value
ZIN = ZOUT (ZERO_Z = Low)
Comment
Binary value
Divider => 1: Binary value +1
1 : 2
1 : 3
1 : 4
1 : 253
1 : 254
1 : 255
1 : 256
Page 15 / 21