Setting The A/B Divider (At A/B Dir To A/B 90°) - Hohner IT 210 Operating Manual

Level converter, direction signal decoder and programmable pulse divider
Table of Contents

Advertisement

If a change takes place at the BIN input signal (A/B dir), the direction of the A/B 90 °
signal changes at the output. Here is a division 1:2, from the input in relation to the
output.
5.3. Setting the A/B Divider (at A/B Dir to A/B 90°)
The division ratio for the A/B pulses is set at the DIL switches DIL5 and DIL6. The
switch positions use a binary code like shown in the subsequent list. (DIL1/6 = ON,
DIL1/7 = OFF).
DIL5
(Left 8-pole)
1
2
3
4
ON
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
ON
ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF
ON
OFF ON OFF OFF OFF OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
ON
ON ON ON ON ON ON ON ON ON ON
Example: Input A/B dir, output A/B 90 ° with A/B division 1:6 (setting DIL6, 5: OFF ON
OFF)
Division 1:2: See Input/Output Mode Conversion (A/B Divider: All OFF)
It210_01a_oi_e.docx / Jan-20
www.hohner-elektrotechnik.de
Divider [A/B]
(Left 3-pole)
5
6
7
8
1
DIL6
Comment
2
3
Binary value
division =>
1 : (Binary value +1) x2
value 1 => 1 : 4
value 2 => 1 : 6
value 3 => 1 : 8
value 4 => 1 : 10
value 5 => 1 : 12
1 : 1026
1 : 2050
1 : 4096
...etc.
Page 11 / 21