Operating Manual Level Converter, Direction Signal Decoder and programmable Pulse Divider IT 210 Your partner for standard and special designs - precise, reliable and fast -...
2018 Legal notices: All contents included in this manual are protected by the terms of use and copyrights of Hohner Elektrotechnik GmbH. Any reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by Hohner Elektrotechnik GmbH.
Page 4
Legal notices: All contents included in this manual are protected by the terms of use and copyrights of Hohner Elektrotechnik GmbH. Any reproduction, modification, usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by Hohner Elektrotechnik GmbH.
- in accordance to the “Technical Specifications” (see chapter 8). The device is not suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard. It210_01a_oi_e.docx / Jan-20 Page 4 / 21 www.hohner-elektrotechnik.de...
Please find all respective hints and rules on www.hohner-elektrotechnik.de. 1.4 Cleaning, Maintenance and Service Notes To clean the front of the unit please use only a slightly damp (not wet!), soft cloth.
Page 7
(if necessary). Unauthorized opening and repairing can have negative effects or failures to the protection-measures of the unit. It210_01a_oi_e.docx / Jan-20 Page 6 / 21 www.hohner-elektrotechnik.de...
All settings are made on the DILL switches on the housing. The device consists of a compact housing with screw terminals and can be mounted on a DIN rail.Block diagram 3. Block diagram It210_01a_oi_e.docx / Jan-20 Page 7 / 21 www.hohner-elektrotechnik.de...
BOUT output signal. (A/B dir). There is no division. Case 2: Input A/B Dir, Output A/B 90° DIL1/6 = ON, DIL1/7 = OFF with A/B Divider setting: DIL5, 6 = all OFF It210_01a_oi_e.docx / Jan-20 Page 10 / 21 www.hohner-elektrotechnik.de...
ON ON ON ON ON ON ON ON ON ON 1 : 4096 Example: Input A/B dir, output A/B 90 ° with A/B division 1:6 (setting DIL6, 5: OFF ON OFF) Division 1:2: See Input/Output Mode Conversion (A/B Divider: All OFF) It210_01a_oi_e.docx / Jan-20 Page 11 / 21 www.hohner-elektrotechnik.de...
5.6. Informationen over the signal change A/B Dir Signal changes from B (direction) should appear shortly before or latest at the same time as the A flank so that the change can be detected correctly. It210_01a_oi_e.docx / Jan-20 Page 14 / 21 www.hohner-elektrotechnik.de...
ON OFF ON ON ON ON ON ON 1 : 254 OFF ON ON ON ON ON ON ON 1 : 255 ON ON ON ON ON ON ON ON 1 : 256 It210_01a_oi_e.docx / Jan-20 Page 15 / 21 www.hohner-elektrotechnik.de...
Narrow Z pulse (1/4 output-periode) Front (Only applicable to input signals A/B 90°, DIL1/6 = OFF) 8-pole OFF ON The pulse width at the output corresponds to ¼ period of pulse width at the input. It210_01a_oi_e.docx / Jan-20 Page 16 / 21 www.hohner-elektrotechnik.de...
A/B signal does not affect the counting sequence (additionally DIL2/1 on OFF, ZIN is used, Z divider not completely set to OFF). DIL1 Front Wide Z pulse (a full encoder turn) 8-pole It210_01a_oi_e.docx / Jan-20 Page 17 / 21 www.hohner-elektrotechnik.de...
ZOUT (see level conversion Z pulse). Note the special case in which the ZERO_A signal can also set the Z output to zero (see Setting to zero of the A/B divider with ZERO_A signal) It210_01a_oi_e.docx / Jan-20 Page 18 / 21 www.hohner-elektrotechnik.de...
DIL switch DIL3/2 refers to the line B, /B and the DIL switch DIL3/3 to the line Z, /Z. An error can only be detected in RS-422 or HTL differential format, all other formats do not trigger an error. It210_01a_oi_e.docx / Jan-20 Page 19 / 21 www.hohner-elektrotechnik.de...