Network Wiring Connections - SMC Networks TigerSwitch SMC6128PL2 Installation Manual

24-port fast ethernet switch
Hide thumbs Also See for TigerSwitch SMC6128PL2:
Table of Contents

Advertisement

M
N
AKING
ETWORK
Make sure each twisted pair cable does not exceed 100 meters (328 ft)
in length.
3. As each connection is made, the Link LED (on the switch)
corresponding to each port will light to indicate that the connection is
valid.
Note: Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure
jamming signals may degrade overall performance for the segment
attached to the hub.

Network Wiring Connections

Today, the punch-down block is an integral part of many of the newer
equipment racks. It is actually part of the patch panel. Instructions for
making connections in the wiring closet with this type of equipment
follows.
1. Attach one end of a patch cable to an available port on the switch, and
the other end to the patch panel.
2. If not already in place, attach one end of a cable segment to the back
of the patch panel where the punch-down block is located, and the
other end to a modular wall outlet.
3. Label the cables to simplify future troubleshooting.
4-4
C
ONNECTIONS

Advertisement

Table of Contents
loading

This manual is also suitable for:

6128pl2

Table of Contents