Warning: When selecting a fiber SFP device, considering safety, please
Hinweis: Bei der Wahl eines Glasfasertransceivers muß für die
1. Remove and keep the LC port's rubber cover. When not connected to
a fiber cable, the rubber cover should be replaced to protect the optics.
2. Check that the fiber terminators are clean. You can clean the cable
plugs by wiping them gently with a clean tissue or cotton ball
moistened with a little ethanol. Dirty fiber terminators on fiber cables
will impair the quality of the light transmitted through the cable and
lead to degraded performance on the port.
3. Connect one end of the cable to the LC port on the switch and the
other end to the LC port on the other device. Since LC connectors are
keyed, the cable can be attached in only one orientation.
4-6
C
ONNECTIONS
make sure that it can function at a temperature that is not less
than the recommended maximum operational temperature of
the product. You must also use an approved Laser Class 1 SFP
transceiver.
Beurteilung der Gesamtsicherheit beachtet werden, das die
maximale Umgebungstemperatur des Transceivers für den
Betrieb nicht niedriger ist als die für dieses Produkts. Der
Glasfasertransceiver muß auch ein überprüftes Gerät der Laser
Klasse 1 sein.