Daikin ERGA06EAV3H Installer's Reference Manual page 263

Hide thumbs Also See for ERGA06EAV3H:
Table of Contents

Advertisement

ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
Error code
HJ-10
Water pressure sensor abnormality
J3-00
OU: Malfunction of discharge pipe thermistor
J3-10
Compressor port thermistor abnormality
J5-00
Malfunction of suction pipe thermistor
J6-00
OU: Malfunction of heat exchanger thermistor
J6-07
OU: Malfunction of heat exchanger thermistor
J8-00
Malfunction of refrigerant liquid thermistor
JA-00
OU: Malfunction of high pressure sensor
JC-00
Low pressure sensor abnormality
JC-01
Evaporator pressure abnormality
L1-00
Malfunction of INV PCB
L3-00
OU: Electrical box temperature rise problem
L4-00
OU: Malfunction of inverter radiating fin
temperature rise
L5-00
OU: Inverter instantaneous overcurrent (DC)
L8-00
Malfunction triggered by a thermal protection
in the inverter PCB
L9-00
Prevention of compressor lock
LC-00
Malfunction in communication system of outdoor
unit
P1-00
Open-phase power supply imbalance
P3-00
Abnormal direct current
P4-00
OU: Malfunction of radiating fin temperature
sensor
PJ-00
Capacity setting mismatch
U0-00
OU: Shortage of refrigerant
U1-00
Malfunction by reverse phase/open-phase
U2-00
OU: Defect of power supply voltage
U3-00
Underfloor heating screed dryout function not
completed correctly
U4-00
Indoor/outdoor unit communication problem
U5-00
User interface communication problem
U7-00
OU: Transmission malfunction between main CPU-
INV CPU
U8-02
Connection with room thermostat lost
U8-03
No connection with room thermostat
15
Troubleshooting
|
Description
Installer reference guide
263

Advertisement

Table of Contents
loading

Table of Contents