To Connect The Domestic Hot Water Pump - Daikin ERGA06EAV3H Installer's Reference Manual

Hide thumbs Also See for ERGA06EAV3H:
Table of Contents

Advertisement

9
|
Electrical installation

9.3.7 To connect the domestic hot water pump

Installer reference guide
130
A
B
5 6 9 10
X 5M
1
3 Fix the cable with cable ties to the cable tie mountings. General information,
see
"9.3.1 To connect the electrical wiring to the indoor
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[9.2.2] DHW pump
[9.2.3] DHW pump schedule
1 Open the following (see
1 User interface panel
2 Switch box
3 Switch box cover
4 Top cover
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
5 6 9 10
S2S
A
"7.2.4 To open the indoor
ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
S3S
B
4
unit" [
 120].
4
unit" [
 76]):
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
4
3
2
1

Advertisement