Electrical installation

9.3.2 To connect the main power supply

Installer reference guide
122
1
3
It is important that the fixing plate of terminals is NOT in service position, while
cables are connected to one of the terminals. Otherwise the cables could be too
short.
1 Open the following (see
1 User interface panel
2 Switch box
3 Switch box cover
4 Top cover
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection cable Wires: (3+GND)×1.5 mm²
Power supply indoor
unit
2
1
4
4,8 mm
X12M
"7.2.4 To open the indoor
Wires: 1N+GND
Maximum running current: 6.3 A
2
4
unit" [
 76]):
ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01