Checks After Starting Engine; Cooling Water - Yamaha LF250 Owner's Manual

Hide thumbs Also See for LF250:
Table of Contents

Advertisement

Available languages

Available languages

3.
Turn the main switch to "
TIP:
Dual engine users: When the main switch is
turned on, the buzzer operates for a few sec-
onds then stops automatically. The buzzer
also operates if one of the engines stalls.
4.
Turn the main switch to "
and hold it for a maximum of 5 seconds.
ON
START
5.
Immediately after the engine starts, re-
lease the main switch to return it to "
(on). NOTICE: Never turn the main
" (on).
" (start),
ON
START
ZMU04596
ZMU05830
switch to "
gine is running. Do not keep the start-
er motor turning for more than 5
seconds. If the starter motor is turned
continuously for more than 5 seconds,
the battery will be quickly discharged,
thus making it impossible to start the
engine. The starter can also be dam-
aged. If the engine will not start after 5
seconds of cranking, return the main
switch to "
then crank the engine again.
EMU36511

Checks after starting engine

EMU41361

Cooling water

Check for a steady flow of water from the
cooling water pilot hole. A continuous flow of
water from the cooling water pilot hole shows
that the water pump is pumping water
through the cooling water passages.
TIP:
When the engine is started, there may be a
slight delay before water flows from the cool-
ing water pilot hole.
ECM02251
NOTICE
If water is not flowing out of the cooling
water pilot hole at all times while the en-
gine is running, overheating and serious
damage could occur. Stop the engine and
check whether the cooling water inlet on
the lower case or the cooling water pilot
hole is blocked. Consult your Yamaha
dealer if the problem cannot be located
and corrected.
"
Operation
" (start) while the en-
" (on), wait 10 seconds,
[ECM00193]
61