Stihl RMI 522.0 C Instruction Manual page 174

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 99
Message:
1000 – Rollover
Allowed inclination exceeded
Possible cause:
– Tilt sensor has detected a rollover
Remedy:
– Place robotic mower on its wheels,
check for damage and confirm
message with OK
Message:
1010 – iMOW® raised
Press OK to release
Possible cause:
– Robotic mower has been lifted by hood
Remedy:
– Check movement of hood and confirm
message with OK
Message:
1030 – Hood fault
Check hood
Then press OK
Possible cause:
– No hood detected
Remedy:
– Check hood (movement, firm seating)
and confirm the message with OK
Message:
1105 – Flap open
Operation aborted
Possible cause:
– Flap open during automatic operation
– Flap open during automatic edge
following
Remedy:
– Close the flap (
15.2)
172
Message:
1120 – Hood blocked
Check hood
then press OK
Possible cause:
– Permanent collision detected
– Uneven areas around or underneath
docking station floor plate
Remedy:
– Free robotic mower, remove obstacle or
change routing of perimeter wire if
necessary – then confirm message with
OK
– Check movement of hood and confirm
message with OK
– Level out uneven areas and confirm
message with OK (
9.1)
Message:
1125 – Remove obstacle
Check wire routing
Possible cause:
– Perimeter wire routed inaccurately
Remedy:
– Check routing of the perimeter wire,
check clearances using the
iMOW® Ruler (
12.5)
Message:
1130 – Stuck
Free iMOW®
then press OK
Possible cause:
– Robotic mower has become stuck
– Drive wheels are spinning
Remedy:
– Free robotic mower, level out mowing
area or change routing of perimeter
wire if necessary – then confirm
message with OK
– Clean drive wheels, if necessary
prevent operation during rain – then
confirm message with OK (
Message:
1135 – Outside
Place the iMOW® on the mowing area
Possible cause:
– Robotic mower is located outside
mowing area
Remedy:
– Return robotic mower to mowing area
Message:
1140 – Too steep
Check wire routing
Possible cause:
– Tilt sensor has detected a slope
inclination exceeding 40%
Remedy:
– Change routing of perimeter wire, block
off lawns with slope inclinations
exceeding 40%
Message:
1170 – No signal
Switch on docking station
Possible cause:
– Docking station is switched off
– No reception of wire signal during
operation
– Robotic mower is located outside
mowing area
– Docking station or electronic
components were replaced
Remedy:
– Switch on docking station and give
mowing command
– Check power supply to docking station