Power Supply Assembly - HP Compaq dx6100 Series Technical Reference Manual

Hide thumbs Also See for Compaq dx6100 Series:
Table of Contents

Advertisement

Power and Signal Distribution

7.2.1 Power Supply Assembly

These systems feature power supplies with power factor-correction logic. Four power supplies
are used: a 200-watt power supply for the USDT unit, a 240-watt power supply for the SFF and
ST units, a 300-watt power supply for the MT unit, and a 340-watt power supply for the CMT
unit. All power supplies except that for the MT feature active power factor correction (PFC) and
auto-ranging. The 300-watt power supply uses passive PFC and an AC select switch. Tables 7-1
through 7-4 list the specifications of the power supplies. Note that output load voltages are
measured at the load-side of the output connectors.
200-Watt (USDT) Power Supply Assembly Specifications
Input Line Voltage:
115–230 VAC (auto-ranging) 90–264 VAC
Line Frequency
Input (AC) Current
+3.33 VDC Output
+5.08 VDC Output
+5.08 AUX Output
+12 VDC Output [3]
-12 VDC Output
NOTES:
Total continuous power should not exceed 200 watts. Total surge power (<10 seconds w/duty cycle < 5 %) should not exceed
230 watts.
[1] Minimum loading requirements must be met at all times to ensure normal operation and specification compliance.
[2] Surge duration no longer than 10 seconds with 12-volt tolerance at +/- 10%.
[3] +12 VDC output can be split by the system board to +12 VDC (@ 3 A) and +12 Vcpu (@ 12.5 A) power planes.
240-Watt (SFF/ST) Power Supply Assembly Specifications
Input Line Voltage:
115–230 VAC (auto-ranging)
Line Frequency
Input (AC) Current
+3.3 VDC Output
+5.08 VDC Output
+5.08 AUX Output
+12 VDC Output
+12 VDC Output (Vcpu)
--12 VDC Output
NOTES:
Total continuous power should not exceed 240 watts. Total surge power (<10 seconds w/duty cycle < 5 %) should not exceed
260 watts.
[1] The minimum current loading figures apply to a PS On start up only.
7-2
Table 7-1.
Min.
Range or
Current
Tolerance
Loading [1]
--
47–63 Hz
--
--
--
+ 4 %
0.1 A
+ 3.3 %
0.3 A
+ 3.3 %
0.0 A
+ 5 %
0.1 A
+ 10 %
0.0 A
Table 7-2.
Min.
Range/
Current
Tolerance
Loading [1]
90–264 VAC
--
47–63 Hz
--
--
--
+ 4%
0.1 A
+ 3.3 %
0.3 A
+ 3.3 %
0.0 A
+ 5 %
0.1 A
+ 5 %
0.1 A
+ 10 %
0.0 A
361834-001
Max.
Surge
Current
Current [2]
--
--
--
--
4.0 A
--
12.0 A
12.0 A
10.0 A
10.0 A
2.0 A
2.0 A
15.5 A
18.0 A
0.15 A
0.15 A
Max.
Surge
Current
Current [2]
--
--
--
--
5.0 A
--
19.0 A
19.0 A
14.0 A
14.0 A
3.0 A
3.0 A
7.5 A
9.0 A
12.5 A
12.5 A
0.15 A
0.15 A
Technical Reference Guide
Max.
Ripple
--
--
--
50 mV
50 mV
50 mV
120 mV
200 mV
Max.
Ripple
--
--
--
50 mV
50 mV
50 mV
120 mV
120 mv
200 mV

Advertisement

Table of Contents
loading

Table of Contents