[LOG]
***{ This section is optional. It is not required unless
***{ System defaults are not acceptable. Delete the
***{ single asterisks below to make this section active. }
***{ Log generation/save characteristics
***{ Format: <LogFileName>=<Minutes>,<Days>
***{ Minutes = Frequency to copy to HD (1 - 30 min) }
***{ Note: Values outside this range = 1 min. }
***{ Days = days to save on HD (5 - 30)
***{ Mode = 0 - off (default)
***{
UserLog=10,7,1
SwLog=10,7,0
AlarmLog=10,7,1
VideoLossLog=10,7,1
RS232ALARM section
Note:
• This section is legacy setting for existing WJ-MPU955 and should not be changed.
All RS232C ports can be set in the admin console for the alarm interface. This section describes the
characteristics for the external alarm port only. Other use of the port, such as for an external controller,
must be configured using the admin console.
[RS232ALARM]
***{ This section is optional. It is not required unless
***{ System defaults are not acceptable. Delete the
***{ single asterisks below to make this section active.
***{ Enable/Disable Serial Alarms by port
***{ Format: AlarmPort=<port 1>,<port 2>,<port 3>
***{ port # = use "1" to indicate desired port (only one) }
***{ port # = use "0" to indicate ports not desired
*AlarmPort=1,0,0
ALARMTEXTDISPLAY section
This section sets up the characteristics of the alarm text - whether alarm text only or alarm and action
text.
There is a 38 character maximum for alarm text.
[ALARMTEXTDISPLAY]
***{ This section is optional. It is not required unless
***{ System defaults are not acceptable. Delete the
***{ single asterisks below to make this section active. }
***{ Alarm Text Display format
***{ Format: AlarmTextDisplay=<option>