Terminal Box Gt640; Terminal Box 1Xb1621; Figure 6-2 Terminal Box Gt640; Figure 6-3 Terminal Box 1Xb1621 - Siemens SIMOTICS 1PQ8 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

Terminal box 1XB1631 (Page 70)
Terminal box 1XB1634 (Page 71)
6.2.1

Terminal box GT640

The GT640 terminal box is used only for machines with shaft height 315.
Figure 6-2
The connecting cables are introduced into the GT640 terminal box through the cable glands
with threaded holes 2 x M72 x 2 and 2 x M20 x 1.5. The cable glands are not included in the
standard scope of supply.
You can find additional information here:
● Connecting cables with cable lugs (Page 78)
● Connection without cable lugs (Page 79)
6.2.2

Terminal box 1XB1621

Figure 6-3
The connecting cables are introduced into the 1XB1621 terminal box through the cable glands
with threaded holes 2 x M80 x 2 and 2 x M25 x 1.5. The cable glands are not included in the
standard scope of supply. The version with sealing insert with break-off ring is optional.
SIMOTICS TN Series N-compact 1PQ8
Operating Instructions 11/2018
Terminal box GT640
Terminal box 1XB1621
Electrical connection
6.2 Terminal box
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics tn series

Table of Contents