Roller-Contact Bearings; Uninstalling Roller-Contact Bearings - Siemens SIMOTICS 1PQ8 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

9.2.9

Roller-contact bearings

9.2.9.1

Uninstalling roller-contact bearings

Preparation
● Remove any grease feeders, shock pulse measurement equipment and possibly mounted
● Remove the coupling on the drive end or make the shaft extension freely accessible.
● At the NDE, proceed as follows:
Note
For a schematic diagram of the respective component layout, see the chapter "Spare parts
(Page 135)".
Procedure
1. Remove the bearing mounting components.
2. Pull off the roller bearing together with the grease slinger.
SIMOTICS TN Series N-compact 1PQ8
Operating Instructions 11/2018
instrumentation at the DE and NDE.
– First, uninstall the fan cowl or external fan cowl.
Fan cowl
External fan cowl (Page 124)
– Remove the external fan.
External fan made of metal (Page 125)
External fan made of plastic
– Remove the outer bearing cover if one is being used.
Remove V ring (Page 128).
Removing the labyrinth sealing ring (Page 128).
– Ensure that the inner bearing cover is no longer attached to the bearing housing or end
shield.
– Support the rotor for the removal of bearing housing or end shield.
– If necessary, remove the bearing housing from the end shield.
– Remove the end shield. Depending on the shaft height, roller bearing type and design,
it is either a bearing head version or a bearing housing version.
– Remove the locking ring from the shaft.
Maintenance
9.2 Corrective Maintenance
127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics tn series

Table of Contents