Interlock Circuit For Anti-Condensation Heating (Option); Im B5 Type Of Construction With Support Foot - Siemens SIMOTICS 1PQ8 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

Preparations for use

4.6 Interlock circuit for anti-condensation heating (option)

See also
Set values for monitoring the winding temperature (Page 94)
Setpoint values for monitoring the bearing temperature (Page 94)
4.6
Interlock circuit for anti-condensation heating (option)
If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine.
● Install an interlock circuit that switches off the anti-condensation heating once the main
● Only switch on the anti-condensation heating after the machine has been switched off.
See also
Switching off the anti-condensation heating (Page 99)
Explosion hazard
If the anti-condensation heating is switched on directly after the machine is switched off, the
temperature class or the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
● Only switch on the anti-condensation heating after the motor has been switched off.
4.7

IM B5 type of construction with support foot

● For machines, type of construction IM B5, provide an additional support foot at the NDE.
● Use an appropriately sized support foot with the appropriate rigidity. The support foot must
● There is a threaded hole M36 at the bottom of the machine where you can attach the support
32
machine is switched on.
WARNING
Carefully comply with the data on the anti-condensation heating plate.
The support foot is not included in the scope of supply.
be able to support the total weight of the machine.
The weight of the machine is stated on the rating plate, data on geometry is shown in the
dimension drawing.
foot.