Figure 4-3 Schematic Representation Of A Tandem Drive - Siemens SIMOTICS 1PQ8 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

Preparations for use
4.17 Converter operation
NOTICE
Bearing damage
The bearing insulation must not be bridged. Bearing currents can damage bearings.
● Also for subsequent installation work, such as the installation of an automatic lubrication
● Contact the Service Center, if necessary.
Tandem operation
If you connect two motors in series in "tandem operation", install an insulated coupling between
the motors.
Figure 4-3
NOTICE
Bearing damage
Bearing currents can flow if the coupling between the motors of the tandem drive is not
insulated. This can damage the DE bearings of both motors.
● Use an insulated coupling to link the motors.
See also
Service and Support (Page 155)
If you connect two motors in series in "tandem operation", locate a coupling between the
motors; this coupling should satisfy the Directive 2014/34/EU or the regulations that apply in
the country where the equipment is installed.
48
system or a non-insulated vibration sensor, make sure that the bearing insulation cannot
be bridged.
Driving machine
Motor
Coupling
Schematic representation of a tandem drive
Insulated bearings
Insulated tachometer fitting
Insulated coupling
SIMOTICS TN Series N-compact 1PQ8