10.3 Anti-condensation heating

See also
Guide for Spares on Web (http://support.automation.siemens.com/WW/news/en/25248626)
Rolling bearings
When ordering rolling bearings, in addition to the bearing identification code, the
supplementary specifying code is also necessary for the bearing version. Both of these codes
are stamped on the lubricant plate and specified in the motor documentation, or can also be
taken from the installed bearings.
Always replace the rolling bearings with the identical bearings.
If insulated rolling bearings are fitted, use insulated rolling bearings of the same type as spare
parts. This will prevent any bearing damage being caused by bearing currents.
10.3
Anti-condensation heating
Risk of explosion
If repairs to the anti-condensation heating are not carried out correctly, e.g. if unauthorized
or untested spare parts are used, this can result in explosions during operation in a potentially
explosive gaseous atmosphere. This can result in death, serious injury or material
damage.
Repairing and mounting the anti-condensation heating and the subsequent routine testing
must always be undertaken by experts from the Service Center (Page 155), because this
work requires extensive specialist knowledge. Only authorized and tested spare parts may
be used.