Advertisement
The +ECO line embodies our commitment to environmental concerns. Aware of threats facing the world we live in, Oregon Scientific™ has combined technological know-how, practicality and style to create this line of environmentally friendly products. These products provide practical solutions while enabling you and us to fulfill our environmental responsibility.
Simply detach the solar panel and face it directly towards the sun for a few hours to receive the amount of energy necessary to power the device.
Together we can improve the world we live in.
This product uses two AAA rechargeable batteries which should be charged via the solar panel. For the batteries' first charge, it is strongly advised to charge it for at least 2 hours.
To charge the battery:
5-6 hours of battery charging will normally provide power to operate unit for 2 months.
When the rechargeable battery is nearly flat or when solar panel has been detached, the (green) LED indicator on the main unit and will flash.
TIPS
Solar panel facing: | if you reside in the: |
North | Southern Hemisphere |
South | Northern Hemisphere |
1 piece AAA battery
In the case when the rechargeable battery is flat or nearly flat or when the solar panel has been detached, the AAA battery can act as backup power supply for the main unit.
NOTE: When the rechargeable battery power is exhausted or when the solar panel has been detached, the backlight function will be disabled and the performance of the radio controlled clock may be affected.
Power adaptor (not included)
The adaptor powers the unit and can also be used for charging the rechargeable battery. When connected to the main unit, will be displayed.
NOTE: The main unit and adaptor should not be exposed to wet conditions. No objects filled with liquid, such as vases, should be placed on the main unit and adaptor.
This product can work with up to 3 sensors at any one time to capture temperature readings in various locations.
To set up the remote sensor:
NOTE: Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
The remote sensor reception icon will show the following status:
ICONS | MEANING |
Main unit is searching for sensor(s) | |
A sensor channel has been found | |
No sensor found |
TIP: Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading.
This product is designed to synchronize its clock automatically with a clock signal.
BAR332ES: EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany.
BAR332ESU: UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England.
BAR332ESA: WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado.
To enable / disable clock signal reception:
Press and hold to enable or to disable clock signal reception.
NOTE: Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search.
Clock signal reception indicator:
STRONG SIGNAL | WEAK / NO SIGNAL |
To set the clock manually, disable the clock signal reception first.
The settings order is: time zone, 2/24 hr format, hour, minute, year, calendar mode (month – day / day – month), month, day and language.
BAR332ES / BAR332ESU: Time zone offset sets the clock +/- 23 hours from the received clock signal time. If you have deactivated the clock signal reception, do not set a value for time zone.
NOTE: If you enter + in the time offset setting, this will give you your local time plus one hour. If you are in the US (BAR332ESA) set the clock to:
PA for Pacific time
MO for Mountain time
CE for Central time
EA for Eastern time
NOTE: The language options are English (E), German (D), French (F), Italian (I), Spanish (S) and Russian (R).
To select clock display:
Press to toggle between clock with seconds, clock with weekday and calendar.
To set the alarm:
To activate / deactivate alarm:
Press .
To silence the alarm:
To display alarm:
Press .
To toggle temperature unit:
Press °C / °F.
To toggle between each outdoor sensor's readings:
This product forecasts the next 2 to 24 hours of weather forecast within a 30-50 km (19-31 mile) radius.
Sunny | |
Partially cloudy | |
Cloudy | |
Rainy | |
Snowy |
Press SNOOZE to activate backlight for 3 seconds.
Press RESET to return to the default settings.
TYPE | DESCRIPTION |
L x W x H | 58 x 87 x 55mm (6.2 x 3.4 x 2.2 in) |
Weight | 280 g (9.88 oz) without battery |
Signal frequency | 433 MHz |
Power | 2 x UM-4 (AAA) rechargeable batteries; 6V AC adaptor (not included) 1 x UM-4 (AAA) battery (for backup) |
TYPE | DESCRIPTION |
L x W x H | 96 x 50 x 22mm (3.78 x 1.97 x 0.87 in) |
Weight | 62 g (2.22 ounces) without battery |
Transmission range | 30 m (98ft) unobstructed |
Temperature range | -20°C to 60°C (-4°F to 140°F) |
Power | 1 x UM-3 (AA) 1.5 V battery |
NOTE: The technical specifications for this product and the contents of the user manual are subject to change without notice.
NOTE: Features and accessories will not be available in all countries. For more information, please contact your local retailer.
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit:
www2.oregonscientific.com/service/support.asp
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
Hereby, Oregon Scientific, declares that this +ECO Solar Weather Clock (model: BAR332ES / BAR332ESU/ BAR332ESA) is in compliance with the essential requirements and other relevant provisions of Directive 999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVED COMPLIED All EU countries, Switzerland Ch and Norway N
This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
DEClARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please visit our website at www2. oregonscientific.com/service for all enquiries.
We
Name: Oregon Scientific, Inc.
Address: 986 SW 95th Ave.,Tualatin, Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product is in conformity with Part 5 of the FCC Rules. Operation is subject to the following two conditions:
Product No.: | BAR332ES / BAR332ESU / BAR332ESA |
Product Name: | +ECO Solar Weather Clock |
Manufacturer: | IDT Technology Limited |
Address: | Block C, 9/F, Kaiser Estate, Phase, 4 Man Yue St., Hung Hom, Kowloon, Hong Kong |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Oregon Scientific BAR332ES, BAR332ESA, BAR332ESU - ECO Solar Weather Clock Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the BAR332ES that isn't answered in the manual? Leave your question here.