C Service Inputs

POSITION
Program Items
LLC Probe
C1
continuity
Brew Basket
C2
Sensor
Tank
C4
Temperature
C5
USB Drive
C6
Keyboard Test

D Service Outputs

POSITION
Program Items
D1
Heater SSR Test
D2
Fill Valve Test
Lt (left)
D3
Brew Valve Test
Rt (right)
D4
Brew Valve Test
Lt (left)
D5*
Bypass
Valve Test
Rt (right)
D6*
Bypass
Valve Test
LT (left)
D7*
Brew Basket
Lock Test
RT (right)
D8*
Brew Basket
Lock Test
*Active if bypass and brew basket lock is installed and activated on equipment.
Bypass must be installed and is activated in F4-SERVICE MENU, Brew basket lock is located in F5
Single series displays right side only Left Valve display is only for twin side brewer.
D12
LCD Brightness
D13
LED Brightness
Go to fetco.com for the latest versions of all information
Brewer Sensors and Keypad
Factory set Default
Programming Range
Direct read
L-YES R-YES
Direct read
NO
Calibrate
Test Valves and Heaters; Set screen brightness
Factory set Default
Press button 2 to test
(button 1 stops test)
Press button 2 to test
(button 1 stops test)
(Press to test)
(Press to test)
(Press to test)
(Press to test)
(Press to test)
(Press to test)
Brightness=90%
Brightness=60%
Increments
Reading of tank
≈850- LOW
water resistance in
≈1600-HIGH
TDS
YES or NO
Hot water tank
temperature
(not in use)
Checks buttons
under membrane
cover
Programming
Increments
Range
Activates heater
Toggle +/-
Default is 10 sec..
OFF or ON
Activates valve
Toggle +/-
Default is 10 sec.
OFF or ON
Activates valve
Toggle +/-
Default is 10 sec.
OFF or ON
Activates valve
Toggle +/-
Default is 10 sec.
OFF or ON
Activates valve
Toggle +/-
Default is 10 sec.
OFF or ON
Activates valve
Toggle +/-
Default is 10 sec.
OFF or ON
Activates Brew
Toggle +/-
Basket Lock
OFF or ON
Activates Brew
Toggle +/-
Basket Lock
OFF or ON
20-100%
20-100%
User Guide & Operator instructions
Page 9
Notes
Nominal values
Actual values
Follow directions on
YES/NO
the touch screen
Notes
Energizes Heater(s)
WARNING!
Service use only.
Press To Test
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Press To Test
Press To Test
Adjust LCD screen
5%
brightness only-Not for
LEDs under buttons
Adjust LED button
5%
brightness only-Not for
the screen display LCD
P212e0August 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-1242

Table of Contents