Rheem STELLAR 850 Series Owner's Manual And Installation Instructions page 33

Gas domestic outdoor water heater
Table of Contents

Advertisement

INSTALLATION
REDUCING HEAT LOSSES
The cold water line to and the hot water line from the water heater must be
insulated in accordance with the requirements of AS/NZS 3500.4. The insulation
must be weatherproof and UV resistant if exposed.
ANODE
The vitreous enamel lined cylinder of the water heater is only covered by the
Rheem warranty when the total dissolved solids (TDS) content in the water is
less than 2500 mg/L and when the correct colour coded anode is used. If an
incorrect colour coded anode is used in the water heater, any resultant faults will
not be covered by the Rheem warranty. In addition, the use of an incorrect colour
coded anode may shorten the life of the water heater cylinder.
The correct colour coded anode for the water supply being used must be
selected and fitted to the water heater for the Rheem warranty to apply to the
"Water Supplies"
water heater cylinder (refer to
on page 19 and the
Anode
Selection table
on page 19). The black anode is typically fitted as standard.
If an incorrect anode is used, there is also the possibility the anode may become
overactive and hydrogen gas could accumulate in the top of the water heater
during long periods of no use. In areas where this is likely to occur, the installer
should instruct the householder on how to dissipate the gas safely (refer to
"Caution"
on page 20).
SADDLING - PIPE WORK
To prevent damage to the cylinder when attaching pipe clips or saddles to the
water heater jacket, we recommend the use of self-drilling screws with a
maximum length of 13 mm. Should pre drilling be required, extreme caution must
be observed when penetrating the jacket of the water heater.
Note: If the cylinder is damaged as a result of attaching pipe clips or
saddles to the jacket, any resultant faults will not be covered by the Rheem
warranty.
33