3. Mount the flexible link rail "V2"
4. Mount the flexible link rail "V3"
SINAMICS SM150 6SL3845-7NN46-7AA2
Operating Instructions Rev.201910281345 EXAMPLE
①
Busbar mounting points, bolt length 45 mm
②
Spacer, bolt length 70 mm
③
Spacer mounting points, bolt length 70 mm
④
Flexible busbar "V2"
– First screw the three spacers
– Screw the link rail left and right onto the two fastening points
– Screw the link rail onto the spacers.
①
Busbar mounting points, bolt length 45 mm
②
Spacer mounting points, bolt length 70 mm
⑤
Flexible busbar "V3"
– Screw the link rail left and right onto the two fastening points
– Screw the link rail onto the spacers.
④
. Tighten all screws with a torque of 50 Nm.
②
onto the link rail.
⑤
. Tighten all screws with a torque of 50 Nm.
Installation
5.8 Connecting the DC bus
①
of the busbars "A2".
①
of the busbars "A3".
85