Dinion
XF
| Installation Manual
Install I/O --> Alarm submenu
Function
Selection
ACTIVE
NONE, HIGH, LOW Selects active_HIGH or active_LOW for the
ACTION
NONE, MODE1,
MODE2, MODE3
ALARM
VMD, REMOTE
OUT
EXIT
Install sync submenu
Function
Selection
SYNC
INTERNAL,
LINE LOCK,
GENLOCK
DETECTED
SYNC
VPHASE
0, 2, ... 358
HPHASE
-25, ..., 0, ... +125
EXIT
Note
VPHASE and HPHASE cannot be accessed if there is no valid locking
signal.
Bosch Security Systems | 2003-10 | V0.5
Description
alarm input connector. Select NONE to disable
alarm switching.
Selects the operating mode of the camera upon
switching the alarm input.
Select VMD to close the output relay upon VMD
alarms. Select REMOTE to make the output relay
available to remote communication devices.
Return to the I/O menu
Description
Select INTERNAL for free running camera
operation, select LINE LOCK to lock to the power
supply frequency, select GENLOCK to lock to the
signal supplied to the external sync input.
Shows the actual sync mode used by the camera.
Adjusts the vertical phase offset (when in LINE
LOCK mode and a valid power supply frequency
is detected).
Adjust the horizontal phase offset (when in EXT
lock mode and a valid input signal is detected)
Return to the INSTALL menu