Problem
The suction turbine will not switch on. – Check the mains cable, mains plug, fuse, socket and fill level sensors (35).
The suction turbine switches off.
The suction turbine will not switch on
again after emptying the container.
The suction power is decreasing.
Dust is escaping when vacuuming
Automatic switch-off (wet vacuuming)
is not working.
The filter cleaning function is not
working.
After-sales service and advice on using products
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or ar-
range the collection of a product in need of servicing or re-
pair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
Bosch Power Tools
Corrective measures
The mode selector switch (5) is set to "automatic start/stop".
– Set the mode selector switch (5) to the "vacuuming" symbol or switch on the
power tool plugged into the electric socket (3).
– Empty the container (1).
– Switch the dust extractor off and wait five seconds before switching it back on.
– Clean the fill level sensors (35) and the space between the fill level sensors (35)
using a brush.
– Remove any blockages from the suction nozzle, suction tube (29), vacuum hose
(21) or flat-pleated filter (24).
– Change the disposal bag (23) or dust bag.
– Make sure the filter cover (34) is engaged correctly.
– Place the top part of the dust extractor (8) on correctly and close the catches (9).
– Change the flat-pleated filter (24).
– Check that the flat-pleated filter (24) has been fitted correctly.
– Change the flat-pleated filter (24).
– Clean the fill level sensors (35) and the space between the fill level sensors (35)
using a brush.
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
– Push the SFC+ switch (18) backwards (position I).
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch-pt.com.au
www.bosch-pt.co.nz
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
English | 23
1 609 92A 4LX | (16.11.2018)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Professional gas 35 l sfc+

Table of Contents