York AFFINITY YAFT026 Installation Manual page 48

Geothermal heat pumps single and dual capacity
Hide thumbs Also See for AFFINITY YAFT026:
Table of Contents

Advertisement

AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
Wiring Schematics cont.
Aurora Advanced with 5-Speed ECM
1
1
Ext Pump
Orange(9)
1
1
Pump
1/2 hp Total
PB1
PB1
G G G
208-230/60/1
2
2
Pump
2
2
Brown(10)
VARIABLE
VARIABLE
SPEED PUMP
SPEED PUMP
HIGH VOLTAGE
HIGH VOLTAGE
SEE 97 P92 7-01
SEE 97 P92 7-01
PRESSURE
TRANSDUCER
GND
GND
GND
1
1
1
Black
Black
OUT
OUT
OUT
2
2
2
White
White
White
5DC
5DC
5DC
3
3
3
Red
Red
REFRIGERATION
OPTION
Brown
Brown
T
T
Brown
Brown
Gray
T
Gray
FLOW METER
GND
GND
3
3
3
3
3
Green
OUT
OUT
2
2
2
2
2
White
5DC
5DC
4
4
4
4
4
Brown
Purple
T
Purple
(Aurora Expansion Board)
(Aurora Expansion Board)
(Aurora Expansion Board)
White
T
White
PERFORMANCE
OPTION
Pump Sl ave
Pump Sl ave
Input/Outp ut
Input/Outp ut
VARIABLE
VARIABLE
SPEED PUMP
SPEED PUMP
LOW VOLTAGE
LOW VOLTAGE
SEE 97 P92 7-01
SEE 97 P92 7-01
Future Use
Smart Grid
Smart Grid
Home
Home
Automati on
Automati on
AID Tool
MODULATING VALVE
AXB BOARD
1
White
NO TE: 10
Green
2
Communicating
Red
Thermostat
C
R
GND
1
24 VAC
2
ABC BOARD
0-10DC
3
Violet(8)
Violet(7)
See Figure 1 for
See Figure 1 for
DHW wiring.
DHW wiring.
White
Not Used
White
Status
Status
Black
G
G
Solenoid
Black
Orange
Analog Output 0-10VDC
Orange
AXB™
AXB™
AXB™
Blue
Blue
Red
Red
Black
Black
Brown
Brown
OFF
OFF
ON
ON
Modbus Add. ID
Modbus Add. ID
1
1
PRESSURE
Future Use
Future Use
2
2
TRANSDUCER
Black
1
3
3
Future Use
Future Use
White
2
4
4
Acc 2 – Dip 1
Acc 2 – Dip 1
Red
3
5
5
Acc 2 – Dip 2
Acc 2 – Dip 2
REFRIGERATION
OPTION
Blue
Blue
SW1
SW1
Blue
T
T T
Pink
Pink
Pink
Pink
T T
T
HOT WATER
OPTION
LO
LO
R
R
C
C
O
O
G
G
Y1
Y1
Y2
Y2
W
W
DH
DH
Traditional
Thermostat
Green/Yellow
Green/Yellow
S
S
S
C
C
C
Blue
Blue
Blue
R
R
R
Red
Red
Black
Black
CC
CC
T2
T2
T1
T1
Tan
Tan
Ru n
Ru n
Ca pac itor
Ca pac itor
(16)
(16)
L2
L2
L1
L1
CT
Black(3)
Black(2)
G G
Unit Power
Accessory 2
SV
208-230/60/1
Output
Valve
Capacitor
Capacitor
CT
CT
Compressor
Common CT
NOTE 8
Auxi liary
Heat CT
NOTE 7
Blower CT
Blower CT
GND
OUT
5DC
P9
P9
C
C
EH1
EH1
CC F
CC F
R
R
F FG CC CCG
F FG CC CCG
CC2
CC2
P2
P2
ES
ES
LS
LS
ALM
ALM
K5-Alarm
K5-Alarm
ALG
ALG
Relay
Relay
ACC COM
ACC COM
ACC NO
ACC NO
K6-Acc
K6-Acc
ACC NC
ACC NC
Relay
Relay
LO
LO
R
R
C
C
O/B
O/B
G
G
Y1
Y1
Y2
Y2
W
W
DH
DH
P1
P1
Com2
Com2
Com1
Com1
LED4
LED4
LED5
LED5
G
G
G
G
RS485 NET
RS485 NET
R
R
RS485 NET
RS485 NET
C
C
C
C
R (-) (+)
R (-) (+)
P8
P8
P7
P7
Green(11)
48
CT
Brown
NOTE 2
BLOWER CURRENT
TRANSDUCER
(CT)
Black/White (5)
2
Gray/White (4)
1
3
NOTE 1
PB2
Blue
240V
Black
Red
208V
NOTE 5
Gray
Tan
Red
Blue
Black
Transformer
Transformer
Optional
Optional
Ultra Tech
Ultra Tech
RV
FP1
FP2
LP
CS
CS
RCP
RCP
RCP
CC2
CC2
CC2
CC2
CC2
CC2
P5
P5
REVREV FP1 FP1 FP2 FP2 LPS LPS HPSHPS
REVREV FP1 FP1 FP2 FP2 LPS LPS HPSHPS
HI
HI
LO
LO
G
G
Status
Status
SW1
SW1
Aurora Base Control™
Aurora Base Control™
LED3
LED3
(ABC)
(ABC)
G
G
Test Mode
Test Mode
FP1 – 15°F/30°F
FP1 – 15°F/30°F
FP2 – 15°F/30°F
FP2 – 15°F/30°F
Acc – Dip 4
Acc – Dip 4
Acc – Dip 5
Acc – Dip 5
CC – Dual/Si ngle
CC – Dual/Si ngle
L Output Type
L Output Type
Future Use
Future Use
RS485 EXP
RS485 EXP
Y1
Y1
G
G
CC
CC
C
C
R (-) (+)
R (-) (+)
CO
CO
C
C
EH1
EH1
C
C
EH2
EH2
P6
P6
P3
P3
Brown(23)
Black(21)
Black(20)
Condensate
NOTE 3
NOTE 3
P11
P11
5
5
4
4
Orange
Green
3
3
2
2
Brown
1
1
Green
5 Speed ECM
5 Speed ECM
Blower Motor
Blower Motor
Orange
5
5
4
4
3
3
2
2
1
1
C
C
NOTE 9
NOTE 9
Yellow
24V
24V
Black/White
HP
P4
P4
C
C
R
R
F1-3A
F1-3A
F
F
PWM
PWM
CFM
CFM
1 - Switch blue and re
1 - Switch blue and re
2 - The blk/wh and g
2 - The blk/wh and g
3 – When Auxiliary H
3 – When Auxiliary H
heat unit. The auxilia
heat unit. The auxilia
C
C
Faul t
Faul t
Auxiliar y Heat kit inst
Auxiliar y Heat kit inst
LED1
LED1
P13
P13
R
R
4 – Low voltage wirin
4 – Low voltage wirin
Off
Off
On
On
5 - Y2 input wire Tan
5 - Y2 input wire Tan
1
1
6 - Wires provided fo
6 - Wires provided fo
2
2
RV – B/O
RV – B/O
3
3
7 – Br own blower po
7 – Br own blower po
4
4
8 – Field Connected:
8 – Field Connected:
5
5
6
6
Cur rent Transducer i
Cur rent Transducer i
7
7
8
8
9 - Refer to units 5 S
9 - Refer to units 5 S
SW2
SW2
factory settings.
factory settings.
Config
Config
10 - Wiring harness
10 - Wiring harness
LED2
LED2
Y
Y
11 - Field installed S
NOTE 6
NOTE 6
To P2 on
Electric Heat
Board
Black(22)