York AFFINITY YAFT026 Installation Manual page 25

Geothermal heat pumps single and dual capacity
Hide thumbs Also See for AFFINITY YAFT026:
Table of Contents

Advertisement

Blower Performance Data cont.
Single Speed Unit with 5-Speed ECM Motor
Motor
Motor
T'stat
Model
Speed
Tap
Cnct.
High
5
W
Med High
4
Y1
022
Med
3
Med Low
2
G
Low
1
High
5
Med High
4
W
030
Med
3
Y1
Med Low
2
Low
1
G
High
5
W
Med High
4
Y1
036
Med
3
Med Low
2
Low
1
G
High
5
Med High
4
W
042
Med
3
Med Low
2
Y1
Low
1
G
High
5
Med High
4
W
048
Med
3
Y1
Med Low
2
Low
1
G
High
5
W
Med High
4
060
Med
3
Med Low
2
Y1
Low
1
G
High
5
W
Med High
4
Y1
070
Med
3
Med Low
2
Low
1
G
Factory speed settings are in Bold
Air flow values are with dry coil and standard filter
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg., and 500 fpm by 0.16 in. wg.
Highest setting is for auxiliary heat (W) and lowest setting is for constant blower (G). The "Y1" and "Y2" settings must be between the
"G" and "W" settings.
The gray wire is not factory wired to the motor and is tied to the wire harness. This wire can be field connected and can be used with 3HT/2CL
thermostats or IntelliZone2 to deliver the required air flow for the Y2 signal.
5-Speed ECM Constant Torque Motors
The 5-Speed ECM is a 'Constant Torque' ECM motor and delivers
air flow similar to a PSC but operates as efficiently as an ECM Motor.
Because it's an ECM Motor, the 5-Speed ECM can ramp slowly up or
down like the ECM motor. There are 5 possible speed taps available
on the 5-Speed ECM motor with #1 being the lowest airflow and #5
being the highest airflow. These speed selections are preset at the
time of manufacture and are easily changed in the field if necessary.
If more than one tap are energized at the same time, built in logic
gives precedence to the highest tap number and allows air flow to
change with G, Y1, Y2 and W signals or with Fan, CC, CC2, and
E1 output signals. Each of those 5 speeds has a specific 'Torque'
value programmed into the motor for each speed selection. As
static pressure increases, airflow decreases resulting in less
torque on the rotor. The motor responds only to changes in torque
and adjusts its speed accordingly.
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
Blower
Motor
0
0.05
0.10
Size
HP
980
960
940
890
878
865
9 x 7
1/2
830
815
800
780
760
740
625
593
560
1407 1381 1354 1327 1300 1267 1233 1201 1168 1131 1094 1009
1146 1134 1122
9 x 7
1/2
1023 1012 1001
978
962
946
795
777
759
1530 1503 1476 1453 1429 1413 1397 1376 1355 1342 1329 1276 1231 1173
1413 1388 1363 1342 1321 1303 1285 1263 1240 1226 1212 1173 1016
11 x 10
1/2
1355 1325 1294 1276 1258 1235 1212 1188 1164 1144 1123
1336 1299 1261 1242 1222 1202 1181 1157 1132
1243 1182 1121 1061 1000
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492
11 x 10
1
1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372
1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492
11 x 10
1
1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372
1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002
2245 2230 2214 2194 2173 2155 2136 2120 2103 2087 2070 2032 1998 1957 1910 1825
2092 2073 2054 2035 2015 1995 1975 1958 1940 1922 1904 1880 1843 1806 1767 1728
11 x 10
1
1951 1931 1910 1889 1868 1850 1831 1812 1793 1774 1755 1722 1688 1654 1612 1562
1812 1796 1780 1761 1741 1718 1695 1682 1668 1651 1633 1591 1555 1518 1480 1433
1682 1661 1640 1616 1591 1573 1555 1533 1510 1495 1480 1441 1400 1351 1316 1263
2472 2454 2435 2414 2393 2371 2349 2328 2306 2289 2271 2230 2189 2121 2033 1936
2271 2248 2225 2205 2184 2166 2147 2129 2110 2094 2078 2039 2011 1977 1930 1846
11 x 10
1
2133 2115 2096 2072 2047 2030 2013 1996 1979 1965 1950 1909 1873 1837 1793 1748
2008 1985 1962 1939 1915 1898 1880 1862 1843 1828 1812 1774 1742 1703 1669 1635
1806 1784 1761 1742 1722 1696 1669 1656 1642 1625 1607 1564 1527 1490 1443 1404
Airflow (cfm) at External Static Pressure (in. wg)
0.15
0.20
0.25
0.30
0.35
930
920
905
890
875
845
825
813
800
785
788
775
755
735
723
703
665
653
640
620
535
510
495
480
455
1111
1099 1085 1071 1062 1052 1042 1031
985
969
959
949
937
934
922
907
891
882
748
737
718
698
686
964
928
856
The 5-Speed ECM motor is powered by line voltage but the motor
speed is energized by 24 VAC.
5-Speed ECM Benefits:
- High efficiency
- Soft start
- 5 speeds with up to 4 speeds on-line
- Built in logic allows air flow to change with G, Y1, Y2
and W signals
- Super efficient low airflow continuous blower setting (G)
25
0.40
0.45
0.50
0.60
0.70
860
840
820
800
745
770
753
735
710
665
710
690
670
640
600
600
585
570
-
-
430
410
390
-
-
-
966
-
925
913
901
-
-
872
858
843
-
-
673
650
626
-
-
982
909
1111
1090
937
874
784
744
703
647
592
0.80
0.90
1.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
946
-
-
883
-
-
830
-
-
-
-
-
-
-
-
-
-
-
-
988
-
-
-
-
-
-
-
-
-
-
988
-
-
6/14/12