York YHJF18 Technical Manual

York YHJF18 Technical Manual

Split-system heat pumps 14.5 seer – r-410a 1.5 thru 5 nominal tons, 1 phase
Hide thumbs Also See for YHJF18:

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
HEAT PUMPS
14.5 SEER – R-410A
MODELS:
YHJF18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal appli-
cations to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers. Many
matches meet Federal Tax Rebate program.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
• PROTECTED COMPRESSOR - The complete scroll com-
• DURABLE FINISH - The cabinet is made of pre-painted
• LOWER INSTALLED COST - Installation time and costs are
• TOP DISCHARGE - The warm air from the top mounted fan
• SWEPT FAN BLADE SOUND JACKET - The upward air
ISO 9001
Certified Quality
Management System
• LOW MAINTENANCE - Long life permanently lubricated
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
• SECURED SERVICE VALVES - Secured re-usable service
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for out-
copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.
pressor line is internally protected against high pressure,
temperature, and externally by a factory installed high pres-
sure switch. This is accomplished by the simultaneous oper-
ation of high pressure relief valve and a temperature sensor
which protects the compressor if undesirable operating con-
ditions occur. A liquid line filter-drier further protects the com-
pressor.
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
flow carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and compres-
sor operating sounds. The swept wing fan blade and com-
pressor sound jacket futher reduce noise levels.
motor-bearings need no annual servicing.
nections, and a single panel covering the electrical controls
make for easy servicing of the unit.
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
door application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.
510667-YTG-A-0409

Advertisement

loading

Summary of Contents for York YHJF18

  • Page 1 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Physical And Electrical Data

    4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. YHJF18 YHJF24...
  • Page 3 YHJF18 Outdoor Unit S41S1 .051/1TVM4F1 .059/1TVM4G1 .063/1TVM4G1 .071/1TVM4H1 .075/1TVM4J1 Required Orifice or TXV Factory Charge, lbs-oz 6 - 15 Indoor Coil FC/MC/PC/UC32 .051 + 0 FC/MC/PC/UC35 .051 + 0 FC/MC/PC/UC37 .051 + 13 FC/MC/PC/UC43 .051 + 13 FC/PC62D3X – AHX30 .051 + 0...
  • Page 4 510667-YTG-A-0409 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL MODEL MV12B YHJF18S41S1 MV12B MV12B YHJF24S41S1 MV12B MV12B YHJF30S41S1 MV16C MV12B YHJF36S41S1 MV16C YHJF42S41S1 MV20D YHJF48S41S1 MV20D YHJF60S41S1 MV20D YHJF18S41S1 AV*36 YHJF24S41S1 AV*36 YHJF30S41S1 AV*36 YHJF36S41S1 AV*36 YHJF18S41S1 AHX30 AHX30 F6FP030...
  • Page 5 COOLING CAPACITY - With High Efficiency Motor Furnaces UNIT FURNACE MODEL MODEL T*(8,L)X*A12 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 Y*(8,L)(C,V)*C16 YHJF18S41S1 Y*9(C,V)*B12 Y*9(C,V)*C16 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*B12 T*9X*C16 T*9X*C20 T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*9X*B12 T*9X*C16 T*9X*C20 YHJF24S41S1 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*B12 Y*9(C,V)*C16 Y*9(C,V)*C20 Y*(8,L)(C,V)*A12...
  • Page 6 510667-YTG-A-0409 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) UNIT FURNACE MODEL MODEL T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*B12 YHJF36S41S1 T*9X*C16 T*9X*C20 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*C16 Y*9(C,V)*C20 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*C16 T*9X*C20 YHJF42S41S1 T*9X*D20 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*C20 Y*9(C,V)*D20 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*C16 T*9X*C20 T*9X*D20 YHJF48S41S1 Y*(8,L)(C,V)*C16...
  • Page 7 HEATING PERFORMANCE - With Air Handler UNIT MODEL* HANDLER MV12B YHJF18S41S1 MV12B MV12B YHJF24S41S1 MV12B MV12B YHJF30S41S1 MV16C MV12B YHJF36S41S1 MV16C YHJF42S41S1 MV20D YHJF48S41S1 MV20D YHJF18S41S1 AV*36 YHJF24S41S1 AV*36 YHJF30S41S1 AV*36 YHJF36S41S1 AV*36 YHJF18S41S1 AHX30 AHX30 F6FP030 YHJF24S41S1 F6FP036 AHX36 AHX36 YHJF30S41S1 F6FP042...
  • Page 8 510667-YTG-A-0409 HEATING CAPACITY - With High Efficiency Motor Furnaces FURNACE MODEL MODEL T*(8,L)X*A12 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 Y*(8,L)(C,V)*C16 YHJF18S41S1 Y*9(C,V)*B12 Y*9(C,V)*C16 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*B12 T*9X*C16 T*9X*C20 T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*9X*B12 T*9X*C16 T*9X*C20 YHJF24S41S1 Y*(8,L)(C,V)*A12 Y*(8,L)(C,V)*B12 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*B12 Y*9(C,V)*C16 Y*9(C,V)*C20 Y*(8,L)(C,V)*A12...
  • Page 9 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE MODEL MODEL T*(8,L)X*A12 T*(8,L)X*B12 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*B12 YHJF36S41S1 T*9X*C16 T*9X*C20 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*C16 Y*9(C,V)*C20 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*C16 T*9X*C20 T*9X*D20 YHJF42S41S1 Y*(8,L)(C,V)*C16 Y*(8,L)(C,V)*C20 Y*9(C,V)*C16 Y*9(C,V)*C20 Y*9(C,V)*D20 T*(8,L)X*C16 T*(8,L)X*C20 T*9X*C16 T*9X*C20 YHJF48S41S1 T*9X*D20 Y*(8,L)(C,V)*C20 Y*9(C,V)*C16...
  • Page 10 510667-YTG-A-0409 HEATING CAPACITY - With High Efficiency Motor Furnaces UNIT VARIABLE SPEED FURNACE MODEL MODEL T*(8,L)X*C20 T*9X*C20 T*9X*D20 YHJF60S41S1 Y*(8,L)(C,V)*C20 Y*9(C,V)*C20 Y*9(C,V)*D20 1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2.
  • Page 11: Typical Installation

    SOUND LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) Test Condition Size RSS Sound Power Calibration 1091 402 Cooling Mode Heating Mode Cooling Mode Heating Mode Cooling Mode Heating Mode Cooling Mode Heating Mode Cooling Mode Heating Mode Cooling Mode Heating Mode Cooling Mode - High Stage Heating Mode - High Stage...
  • Page 12 510667-YTG-A-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF18S41S1 INDOOR COIL MODEL NO. AHX30 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 13 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF24S41S1 INDOOR COIL MODEL NO. AHX30 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 14 510667-YTG-A-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF30S41S1 INDOOR COIL MODEL NO. AHX36 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 15 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF36S41S1 INDOOR COIL MODEL NO. AHX36 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 16 510667-YTG-A-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF42S41S1 INDOOR COIL MODEL NO. AHX60 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 17 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJF48S41S1 INDOOR COIL MODEL NO. F6FP060 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 18 510667-YTG-A-0409 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION CONDENSING UNIT MODEL NO. YHJF60S41S1 INDOOR COIL MODEL NO. AHX60 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C.
  • Page 19 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION CONDENSING UNIT MODEL NO. YHJF60S41S1 INDOOR COIL MODEL NO. AHX60 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C.
  • Page 20 510667-YTG-A-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil AV*36...
  • Page 21 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil AHX36...
  • Page 22 510667-YTG-A-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil AV*36...
  • Page 23 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil AHX42...
  • Page 24 510667-YTG-A-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil F6FP060...
  • Page 25 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil AHX60...
  • Page 26 1.89 4.44 33.83 Variable Speed Furnace 0.99 1.00 0.99 T*(8,L)X*C20 T*9X*C20 T*9X*D20 Y*(8,L)(C,V)*C20 Y*9(C,V)*C20 Y*9(C,V)*D20 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 ID CFM 1800 2000 C.O.P. MBTUH 4.41 4.11 72.83 4.54 3.95 4.57 71.49 4.07 3.58 5.03...