Blower Performance Data cont.
Dual Capacity Unit with 5-Speed ECM
Motor
Motor
T'stat
Model
Speed
Tap
Cnct.
High
5
W
Med High
4
Y2
026
Med
3
Med Low
2
Y1
Low
1
G
High
5
W
Med High
4
Y2
038
Med
3
Y1
Med Low
2
Low
1
G
High
5
W
Med High
4
049
Med
3
Y2
Med Low
2
Y1
Low
1
G
High
5
W
Med High
4
Y2
064
Med
3
Med Low
2
Y1
Low
1
G
High
5
W
Med High
4
Y2
072
Med
3
Med Low
2
Y1
Low
1
G
Factory speed settings are in Bold
Air flow values are with dry coil and standard filter
For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]).
Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg., and 500 fpm by 0.16 in. wg.
Highest setting is for auxiliary heat (W) and lowest setting is for constant blower (G). The "Y1" and "Y2" settings must be between the
"G" and "W" settings.
Setting Blower Speed - 5-Speed ECM
5-Speed ECM blower motors have five (5) speeds of which three
(3) are selectable on single speed and four (4) are selectable on
dual capacity.
CAUTION: Disconnect all power before performing
this operation.
5-Speed ECM Motor Connections - Single Speed
C
C - Black
L - Orange
G - Green
G - Blue
1
Y1 - Red
Connections 1/4 in.
Blower
Motor
0
0.05
Size
HP
1120 1109 1097 1082 1066 1055 1044 1028 1011 1001
1020 1006
9 x 7
1/2
917
906
836
824
735
721
1530 1503 1476 1453 1429 1413 1397 1376 1355 1342 1329 1276 1231 1173
1413 1388 1363 1342 1321 1303 1285 1263 1240 1226 1212 1173 1016
11 x 10
1/2
1355 1325 1294 1276 1258 1235 1212 1188 1164 1144 1123
1336 1299 1261 1242 1222 1202 1181 1157 1132
1243 1182 1121 1061 1000
1934 1910 1886 1871 1855 1827 1799 1780 1760 1747 1734 1700 1659 1617
1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492
11 x 10
1
1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372
1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266
1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002
2245 2230 2214 2194 2173 2155 2136 2120 2103 2087 2070 2032 1998 1957 1910 1825
2092 2073
2054
11 x 10
1
1951 1931 1910 1889 1868 1850 1831 1812 1793 1774 1755 1722 1688 1654 1612 1562
1812 1796 1780 1761 1741 1718 1695 1682 1668 1651 1633 1591 1555 1518 1480 1433
1682 1661 1640 1616 1591 1573 1555 1533 1510 1495 1480 1441 1400 1351 1316 1263
2472 2454 2435 2414 2393 2371 2349 2328 2306 2289 2271 2230 2189 2121 2033 1936
2271 2248 2225 2205 2184 2166 2147 2129 2110 2094 2078 2039 2011 1977 1930 1846
11 x 10
1
2133 2115 2096 2072 2047 2030 2013 1996 1979 1965 1950 1909 1873 1837 1793 1748
2008 1985 1962 1939 1915 1898 1880 1862 1843 1828 1812 1774 1742 1703 1669 1635
1806 1784 1761 1742 1722 1696 1669 1656 1642 1625 1607 1564 1527 1490 1443 1404
High Voltage
Connections
3/16 in.
G
N
L
N - Brown
AUX - Gray
2
3
4
5
Low Voltage
Airflow (cfm) at External Static Pressure (in. wg)
0.10
0.15
0.20
0.25
0.30
991
980
968
950
932
895
884
872
854
836
812
794
776
765
754
707
687
666
653
640
964
928
2035 2015 1995 1975 1958 1940 1922 1904 1880 1843 1806 1767 1728
5-Speed ECM Motor Connections - Dual Capacity
C - Black
L - Orange
G - Green
G - Blue
Y1 - Red
26
0.35
0.40
0.45
0.50
0.60
991
932
922
911
894
876
849
824
812
792
772
754
735
715
703
691
653
622
603
589
574
533
982
1111
1090
937
856
784
744
703
647
High Voltage
Connections
3/16 in.
C
G
N
L
3
4
5
1
2
Low Voltage
Connections 1/4 in.
0.70
0.80
0.90
1.00
839
-
-
-
812
-
-
-
719
-
-
-
631
-
-
-
-
-
-
-
-
-
946
-
-
909
883
-
-
874
830
-
-
592
-
-
-
-
-
-
-
-
-
-
988
-
-
6/14/12
N - Brown
AUX - Gray
Y2 - Tan