Important Data For 1Fw6 External Rotor Cables; Data Of The Power Cable On The Stator; Specifications For The Signal Cable On The Stator - Siemens SIMOTICS T-1FW6 Operating Instructions Manual

Built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6:
Table of Contents

Advertisement

Connection
6.2 Electrical connection
6.2.2

Important data for 1FW6 external rotor cables

6.2.2.1

Data of the power cable on the stator

Table 6-1
Data of the power cable on the stator
Motor type
Frame size
1FW6720-
410 x 75
2PB07-3Axx
1FW6720-
410 x 100
2PB10-2Exx
1FW6720-
410 x 100
2PB10-4Fxx
1FW6720-
410 x 125
2PB12-4Fxx
1FW6720-
410 x 150
2PB14-4Fxx
Relevant for retrofitting a connector
*)
6.2.2.2

Specifications for the signal cable on the stator

Table 6-2
Specifications for the signal cable on the stator
Motor type
Frame size
1FW6720-
All
2PBxx-xxxx
Relevant for retrofitting a connector
*)
70
Max. diameter
No. of cores x
in mm
cross section
in mm
12.3
4 x 4
11
4 x 2.5
18.2
4 x 10
18.2
4 x 10
18.2
4 x 10
Max. diameter
No. of cores x
in mm
cross section
in mm
10.6
6 x 0.5 + 1 x 1
Min. bending
Max. height of
radius
2
in mm
49.2
44
72.8
72.8
72.8
Min. bending
Max. height of
radius
in mm
2
50
1FW6 external rotor built-in torque motors
Operating Instructions, 03/2023, A5E49196960B AC
Required con‐
sleeve
nector size
in mm
23
1.5
18
1
30
1.5
30
1.5
30
1.5
Required con‐
sleeve
nector size
in mm
18
M17
*)
*)

Advertisement

Table of Contents
loading

Table of Contents