Description
3.4 Design
Recommended manufacturers are listed in the Appendix.
3.4.4

Temperature monitoring and thermal motor protection

3.4.4.1

Temperature monitoring circuits Temp-S and Temp-F

The motors are equipped with the two temperature monitoring circuits - Temp‑S and Temp‑F -
that are described below.
• Temp‑S activates the thermal motor protection when the motor windings are thermally
overloaded. In this case the precondition is that Temp-S is correctly connected and evaluated.
For a thermal overload, the drive system must bring the motor into a no-current condition.
• Temp-F is used for temperature monitoring and diagnostics during commissioning and in
operation.
Both temperature monitoring circuits are independent of one another.
The SME12x Sensor Module or the TM120 Terminal Module evaluates the temperature sensor
signals.
You can obtain commissioning information from Technical Support. Contact data is provided in
the introduction.
Temp‑S
All motors are equipped with the following temperature monitoring circuit to protect the motor
winding against thermal overload:
• 2 x PTC 130°C temperature sensor per phase winding U, V, and W, response threshold at
130°C, one of which is reserve
The three PTC temperature sensors (PTC thermistor temperature sensors) of this temperature
monitoring circuit are connected in series with a PTC triplet.
Figure 3-6
To protect the power connection at the enclosure against thermal overload, an additional
PTC 80 °C is connected in series with the PTC 130 °C triplet.
44
PTC triplet
1FW6 external rotor built-in torque motors
Operating Instructions, 03/2023, A5E49196960B AC