Dhw Pump For Disinfection - Daikin EPRA16DAV3 Installer's Reference Manual

Hide thumbs Also See for EPRA16DAV3:
Table of Contents

Advertisement

5
|
Application guidelines

5.4.5 DHW pump for disinfection

Installer reference guide
46
For more information about connecting the recirculation connection, see the
installation manual of the domestic hot water tank.
Configuration
For more information, see "9 Configuration" [
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
Setup
a
b
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d Motorised 3‑way valve (field supply)
e DHW pump (field supply)
f Heater element (field supply)
g Non‑return valve (field supply)
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
4
pump" [
 109].
If the applicable legislation requires a higher temperature than the maximum
tank setpoint during disinfection (see [2-03] in the field settings table), you can
connect a DHW pump and heater element as shown above.
If applicable legislation requires disinfection of the water piping until the tapping
point, you can connect a DHW pump and heater element (if needed) as shown
above.
Configuration
The indoor unit can control DHW pump operation. For more information, see
4
"9 Configuration" [
 116].
4
 116].
g
f
e
d
M
"To connect the domestic hot water
c
EPRA14~18DAV3+W1 + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT W
4P587501-1B – 2020.10