When the heat pump produces domestic hot water, it cannot heat up a space. In
case you need domestic hot water and space heating at the same, we
recommend to produce the domestic hot water during the night when there is
lower space heating demand.
▪
For large DHW consumptions, you can heat up the DHW tank several times
during the day.
▪
To heat up the DHW tank to the desired DHW tank temperature, you can use the
following energy sources:
-
Thermodynamic cycle of the heat pump
-
Electrical booster heater
▪
For more information about:
-
Optimizing the energy consumption for producing domestic hot water, see
4
"9 Configuration" [
-
Connecting the electrical wiring of the standalone DHW tank to the indoor unit,
see the installation manual of the DHW tank, and the addendum book for
optional equipment.
-
Connecting the water piping of the standalone DHW tank to the indoor unit,
see the installation manual of the DHW tank.
Setup
a
b
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d DHW pump (field supply)
e Recirculation connection
f Motorised 3‑way valve (field supply)
▪
By connecting a DHW pump, instant hot water can be available at the tap.
▪
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see
4
pump" [
109].
116].
d
e
f
M
"To connect the domestic hot water
5