Polaris RANGER 570 2017 Owner's Manual For Maintenance And Safety page 68

Hide thumbs Also See for RANGER 570 2017:
Table of Contents

Advertisement

MAINTENANCE
Gearcases
Gearcase Specification Chart
Gearcase
Main Gearcase
(Transmission)
Front Gearcase
Transmission (Main Gearcase)
Always check and change the transmission oil at the intervals outlined in the Periodic
Maintenance Chart beginning on page 61. Maintain the oil level even with the bottom thread
of the fill plug hole.
Refer to the Gearcase Specifications Chart for recommended lubricants, capacities and
torque specifications. See page 92 for the part numbers of POLARIS products.
Fluid Check
The fill plug is located on the rear of the gearcase.
Maintain the fluid level at the bottom of the fill plug hole.
1. Position the vehicle on a level surface.
2. Remove the fill plug.
3. Check the fluid level.
4. Add the recommended fluid to the bottom of the fill
plug hole. Do not overfill.
5. Reinstall the fill plug. Torque to specification.
Fluid Change
The drain plug is located on the bottom of the gearcase.
Access the drain plug through the hole in the skid plate.
1. Remove the fill plug.
2. Place a drain pan under the drain plug.
3. Remove the drain plug. Allow the fluid to drain
completely.
4. Clean and reinstall the drain plug. Torque to
specification.
5. Add the recommended fluid to the bottom of the fill
plug hole. Do not overfill.
6. Reinstall the fill plug. Torque to specification.
7. Check for leaks. Discard used fluid properly.
66
Lubricant
AGL Gearcase
Lubricant &
Transmission Fluid
Demand Drive Fluid
Capacity
Fill Plug(s)
Torque
1200 ml
14-19 Nm
(41 oz.)
275 ml
11-13.6 Nm
(9.3 oz.)
Drain Plug
Torque
14-19 Nm
15 Nm
View from
rear of vehicle
Fill Plug
View from rear left
side of vehicle
Drain Plug

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents