Fans For The 8-Port Poe+ And Poe++ Models - NETGEAR M4250-10G2XF-PoE++ Hardware Installation Manual

Av line of fully managed switches
Table of Contents

Advertisement

manually controlling the fans, see the following manuals, which you can download by
visiting netgear.com/support/download:
• Audio-video user manual
• CLI reference manual
If the fans are functioning in Off mode (which you only can set manually and only on
certain models) or in Quiet mode, the switch automatically manages the fans and turns
on the fans or gradually increases the speed of the fans under the following conditions:
• PoE+ and PoE++ models: Either the temperature detected by the temperature
sensor or sensors exceeds its threshold or a PoE budget is exceeded.
• LED tiles model (M4250-12M2XF): Either the temperature detected by the
temperature sensor exceeds its threshold or the switch processes a full traffic load.
• Aggregation model (M4250-16XF): Either the temperature detected by the
temperature sensor exceeds its threshold or the switch processes a full traffic load.

Fans for the 8-port PoE+ and PoE++ models

The following table describes the thresholds and operational properties of the fans for
the 8-port PoE+ and PoE++ models. (The temperatures in Fahrenheit are rounded
down.)
Table 9. Fan operation properties for the 8-port PoE+ and PoE++ models
Fan Mode
Off mode
Temp. sensor
PoE budget
Load
Fan use
Quiet mode with fan use below 25% (20% for model M4250-10G2XF-PoE++)
Temp. sensor
PoE budget
Load
Fan use
Hardware Overview
AV Line of Fully Managed Switches M4250 Series
M4250-10G2F-PoE+
≤ 93F (34C)
≤ 80W
Full traffic load
Off
< 93F (34C)
≤ 125W
Full traffic load
< 25%
M4250-10G2XF-PoE+
≤ 93F (34C)
≤ 90W
Full traffic load
Off
< 93F (34C)
≤ 240W
Full traffic load
< 25%
39
M4250-10G2XF-PoE++
≤ 100F (38C)
≤ 45W
Full traffic load
Off
< 100F (38C)
≤ 200W
Full traffic load
< 20%