BIONAIRE BCM7305RC - Cool Mist Humidifier Manual

BIONAIRE BCM7305RC - Cool Mist Humidifier Manual

Also See for BCM7305RC:

Advertisement

BIONAIRE BCM7305RC - Cool Mist Humidifier Manual

HOW COOL MIST WORKS

Your Bionaire® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through 3 moisture laden wick filters, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill.

warning NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist.

warning NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.

PRE-OPERATING INSTRUCTIONS

  1. Be sure the humidifier is switched to OFF and the unit isdisconnected from the electrical outlet.
  2. Select a location for your humidifier, on a flat surface, about 4" away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by moisture or water. Place on a moisture-resistant surface.

FILLING THE WATER RESERVOIR

  1. Remove the reservoir from the base of the humidifier andbring to the faucet. Turn the reservoir upside down and twist off the reservoir cap by turning counter clockwise. Fill reservoir with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on reservoir FIRMLY.
  2. When full, carry reservoir to the humidifier and place ontothe base. The reservoir holds 1.2 gallons of water and the base holds 1/3 gallon of water. The reservoir will immediately begin to empty into base.
  3. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

Your humidifier is equipped with a technologically advanced digital Humidistat. You can set the humidifier to run continuously in manual mode or set the digital Humidistat to your desired humidity setting. The digital Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The comfort level ranges between 35% and 65% relative humidity.

Manual Mode Instructions:

  1. Plug the humidifier into a 120V AC electrical outlet.
  2. The display will show the current room humidity.
  3. To start the unit, push the MODE/OFF button once forthe HIGH (3) manual setting.
  4. Press the button again for the MEDIUM (2) manualsetting and again for LOW (1). After the selection is made, the display will return to show the current room humidity.
  5. To stop the unit, press and hold the button for twoseconds, or keep pressing the button until the display reads OFF (OF).

DIGITAL HUMIDISTAT INSTRUCTIONS

(see Figure 1):
DIGITAL HUMIDISTAT INSTRUCTIONS

  1. LED DISPLAY
  2. CONTROL PANEL
  3. UP/DOWN BUTTONS
  4. MODE/OFF BUTTON

To take advantage of the Digital Humidistat, press the MODE/OFF button until the speed is set in either the Auto HIGH (A3), Auto MEDIUM (A2) or Auto LOW (A1) setting. Then adjust the set humidity by using the up and down buttons. Humidity will increase in increments of 5%. When the humidity level is set, the display will return to show the current room humidity. When the room humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically.

warning NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture.

warning NOTE: The Digital Humidistat has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at.

If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water reservoir, base and wick filter to prevent algae or bacteria growth.

USING THE PROGRAMMABLE TIMER

The Digital Humidistat allows the user to program the humidifier to come on at a preset time, or turn off after a set amount of time.

Setting the Off Timer:

  1. Select the Mode and or humidity you wish the humidifierto run in.
  2. While the humidifier is running, press and hold the upand down buttons simultaneously for 2 seconds. The display will flash "00".
  3. By pressing the up and down buttons, program thehumidifier to turn off up to 16 hours later in increments of 1 hour.
  4. After setting the timer, the display will return to show thecurrent room humidity. The timer light will illuminate to show that the timer is activated.
  5. After the predetermined length of time has passed, thehumidifier will automatically shut off.

Setting the On Timer:

  1. While the humidifier is off, press and hold the up anddown buttons simultaneously for 2 seconds.
  2. By pressing the up and down buttons, program thehumidifier to turn on up to 16 hours in advance in increments of 1 hour.
  3. After the preset length of time has passed, the humidifierwill automatically turn on Auto Mode HI at 45% for a preset time of 2 hours.

REMOTE INSTRUCTIONS

  1. Insert 2 AAA batteries into back of remote control.
  2. Press the Mode/Off button on remote to begin operation.
  3. Use the remote to control the same features as the base unit.

warning NOTE: The timer function can only be activated on the base unit. It cannot be activated via the remote control.

warning NOTE: Do not mix new and old batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.

REPLACING THE FILTERS

Through normal use, waterborne minerals and sediment become trapped in the wick filters. The harder your water, the greater the amount of minerals in the water, and the more often you will be able to monitor the life of your filters in your humidifier. You will be able to monitor the life of the filters in your humidifier by checking the Filter Monitor Indicator. After 60 minutes of use, Filter Monitor Indicator will move and indicate your filters condition. New filters will register in the section reading GOOD filter. After frequent use of your humidifier, the Filter Monitor Indicator will let you know when the filters need to be changed (see Figure 2):

When the needle is in the CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filters. It is important to change your filters as indicated to obtain stated performance level.

To replace the filter, follow the steps below:

  1. Turn the unit off and disconnect from the electrical outlet.
  2. Remove the tank and main housing to access the base.
  3. Remove the wick holder from the base of the humidifier.
  4. Remove each individual wick and discard. Do notremove rivet, replacement wicks come equipped with rivets for easy replacement.
  5. Follow the weekly cleaning instructions.
  6. Insert new filters into each section of the wick holdermaking sure the rivet attaches to the wick holder securely.
  7. Do not use wicks without rivets as this will not producethe unit's intended output.
  8. Replace the wick holder into the base and replace mainhousing and then tank.
  9. Repeat Operating Instructions.

It will take about 30 minutes for the humidifier to reach maximum output.
You can purchase replacement filters (Model BWF100) by calling 1-800-253-2764 or by visiting www.bionaire.com.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water reservoir. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

  1. Be sure the unit is OFF and is disconnected from theelectrical outlet.
  2. Remove the housing and the reservoir from the humidifierand place in sink or tub.
  3. Carry the base of the unit to the sink, remove the wickholder and wicks, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. NOTE: the base and wick holder are dishwasher safe TOP RACK ONLY.
  4. Drain the water from the reservoir into the sink and rinsereservoir thoroughly. Wipe clean, and dry with a clean cloth or paper towel.
  5. Put filters back in wick holder, replace on base, replacethe housing, then refill reservoir with cool tap water as instructed earlier in the Filling Instructions. Do not overfill.
  6. Follow Operating Instructions.

WEEKLY MAINTENANCE

To Remove Scale:

  1. Repeat steps 1-4 above.
  2. Clean the base by partially filling the base with one 8-ozcup of undiluted white vinegar, or by using Clean-AwayTM (Model DMS216) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all the interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar.
  3. Rinse with clean warm water to remove the cleaningsolution before disinfecting the reservoir.

To Disinfect Humidifier Base and Reservoir:

  1. Fill humidifier base with 1/4 gallon of water and 1/2 teaspoon of chlorine bleach.
  2. Fill the reservoir 1/2 full with water and 1/2 teaspoon ofchlorine bleach.
  3. Let the solution stand for 20 minutes, swishing every fewminutes. Wet all surfaces.
  4. Carefully empty the base and reservoir after 20 minutes, and rinse with water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel.
  5. Check the Filter Monitor Indicator to see if it is time toreplace the filters. Depending on water hardness in your area, it may be necessary to change the filter every 1-2 months. Re-insert the wick filters into the wick holder.
  6. Refill the water reservoir as directed with cool tap water, replace the humidifier housing, and turn the unit on.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:

  1. Dispose of the filters. DO NOT leave in unit.
  2. Clean, rinse and thoroughly dry the humidifier as directedin weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
  3. Place the humidifier in the original carton and store in acool, dry place.
  4. Order your replacement filter for next year's use.

REPLACEMENT ACCESSORIES

To order the replacement accessories you can do any of the following:

  • Fill out the accessory card found with the product
  • Visit your local retailer
  • Go to www.bionaire.com
  • Call consumer service at 1-800-253-2764

SERVICE INSTRUCTIONS

  1. Do NOT attempt to repair or adjust any electrical ormechanical functions on this unit. Doing so will void the warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
  2. If you need to exchange the unit, please return it in itsoriginal carton, with a sales receipt, to the store where you purchased it. If you are returning the unit more than 30 days after the date of purchase, please see the enclosed warranty.
  3. Should your humidifier require service, please call 1-800-253-2764 in North America for further assistance.
  4. If you have any other questions or comments, feel free to write to us or visit our website www.bionaire.com

Bionaire®
JCS/THG, LLC
303 Nelson Avenue
Neosho, MO 64850

Troubleshooting

Trouble Probable Cause Solution
Unit does not turn on
  • Water spilled in humidistat.
  • Circuit breaker has been tripped.
  • Drain water from base and allow unit to dry for 15 minutes.
  • Check circuit breaker.
Mist output minimal to none.
  • Filter has not absorbed water.
  • Mineral buildup in tray.
  • Humidistat is set too low.
  • Filter needs to be replaced.
  • Wait 15 minutes before starting humidifier.
  • See Weekly Maintenance under Cleaning and Maintenance Instructions. Regular cleaning is recommended to keep the unit functioning properly.
  • Raise the level of humidity by adjusting the humidistat (see Operating Instructions).
  • Replace your filter (BWF100) by calling 1-800-253-2764, or visit www.bionaire.com.
Water leaks from reservoir.
  • Rubber reservoir ring is missing or improperly placed.
  • Cap not tight enough.
  • Remove reservoir cap then replace or reposition ring.
  • Tighten the cap.
Filter turns brown.
  • The filter needs to be replaced.
  • Short filter life.
  • Replace your filter (BWF100) by calling 1-800-253-2764, or visit www.bionaire.com.
  • In areas with hard water the filter will need to be changed more frequently.
Film on water reservoir.
  • Mineral deposits cause film on reservoir to build up.
  • See Daily Maintenance under Cleaning and Maintenance instructions. Regular cleaning is recom mended to keep the unit functioning properly.To order Clean-Away™ (DMS216), call 1-800-253-2764, or visit www.bionaire.com.
Water in reservoir appears cloudy.

☛ Filter needs to be replaced.

☛ Water reservoir filled with warm water.

✔ Replace your filter (BWF100) by calling 1-800-253-2764 or visit www.bionaire.com.

✔ Use cool water to fill the water reservoir – and only use Bionaire® products recommended in this manual.

Unit cycles on/off.
  • Humidifier is reacting to room.
  • Set the digital Humidistat to a higher or lower desired setting.
Very tight reservoir cap.
  • Reservoir cap over tightened.
  • Add liquid soap to cap gasket to ease opening.

FREQUENTLY ASKED QUESTIONS

What are the variables that affect run time?

  • The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:
  1. Air exchange in the room where the humidifier isplaced.
  2. Room construction where the humidifier is placed.
  3. Temperature of the room where the humidifier isplaced.
  4. Humidity levels in the room where the humidifier isplaced.
  5. Movement of occupants and the opening and closingof doors in the room where the humidifier is placed.
  6. Home furnishings in the room where the humidifier isplaced.

How do I remove film on water tank?

  • See Daily Maintenance instructions. Regular cleaning is recommended.

How can I extend the run time?

  • Run your unit on the lowest setting.
  • If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time.
  • Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download BIONAIRE BCM7305RC - Cool Mist Humidifier Manual

Advertisement

Need Assistance?

Do you have a question about the BCM7305RC that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents