Read instructions before operating. Retain for future reference.

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Read all instructions before using the appliance.
  2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
  3. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers.
  4. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4 inches (10 cm) away from the wall for best results.
  5. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity).
  6. WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord.
  7. Never place anything over moisture outlet when the unit is running.
  8. NEVER drop or insert any object into any openings.
  9. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.
  10. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards.
  11. DO NOT use outdoors.
  12. Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
  13. DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wall paper.
  14. Humidifier should be unplugged when not in use.
  15. NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit.
  16. This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer.
  17. NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
  18. Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.
  19. Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity.
  20. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
  21. Never place housing under water flow or immerse in liquids.
  22. Do not plug in the cord with wet hands: electric shock could result.
  23. Do not pour water in any openings other than the water tank.
  24. To prevent damage to surfaces, do not place humidifier under overhanging surfaces.
  25. NEVER operate unit without water in the tank.
  26. Do not move unit after it has been used until unit cools completely.
  27. Use both hands when carrying full tank of water.


THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY.

SAVE THESE INSTRUCTIONS

FEATURES - OPERATIONS

CORD AND PLUG INSTRUCTIONS

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating information placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

ICES STATEMENT

This apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. This Class B digital apparatus complies with Canadian ICES-001.

HOW ULTRASONIC WORKS

An ultrasonic transducer atomizes water, producing refreshing visible cool or warm mist. The temperature of warm mist is between 86 ˚F (30°C) - 104 ˚F (40°C).
NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The humidifier should be placed in a normal temperature environment 41 ˚F (5°C) - 104 ˚F (40°C), otherwise, the humidifier may be destroyed in the cold environment. The recommended humidity level is between 40%-50%.

PRE-OPERATING INSTRUCTIONS

  1. Be sure the humidifier is switched OFF and the unit is disconnected from the electrical outlet.
  2. Select a location for your humidifier, on a flat surface, about 4 inches (10 cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface.

FILLING THE WATER TANK

  1. Remove the tank from the main housing.
  2. Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY.
  3. Place tank back into the humidifier housing. The tank will immediately begin to empty into the base. There will be "gurgling" sound and air bubbles appear in the tank. It takes about 2-5 minutes for air bubbles to disappear and the humidifier is then ready to generate mist.
  4. Plug the humidifier into a 120V electrical outlet.

OPERATING INSTRUCTIONS

Power On/Off
Press the Power Button () to turn the humidifier on.
The humidifier will run at Medium setting and the Tank Light will illuminate. Press the Power Button to manually turn light off the humidifier at any setting.
Tank Light
Your humidifier is equipped with a Tank Light which allows you to see the tank in the dark. Press the Tank Light Button () to see unit and tank water level while in the dark.
Cool/Warm Mist Control
Your humidifier can be selected to generate either cool mist or warm mist by pressing the Cool/Warm Mist Control Button (). Each press of the button will switch between cool and warm, and respective indicator will illuminate. You can also turn the Mist Nozzle in multiple directions to achieve your desired direction for mist output.
NOTE: the warm setting is not designed to be hot. It is just above the standard ambient room conditions to prevent the nasal passages from being too cool from the cool moisture.
Mist Output Setting
You may press the Mist Button to select from H/M/L which means High/Medium/Low mist output levels.


DO NOT move the humidifier with water in the tank or the humidifier base. The moving action of the water may activate the water tank's release nozzle and overfill the humidifier base. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occurs, simply remove the excess water from the humidifier base.

Overview

  1. Carry Handle
  2. Water Tank
  3. Control Panel (see Figure 2 for close-up)
  4. Humidifier Base

Control Panel (close-up)

  1. Timer Button
  2. Tank Light Button
  3. Power Button
  4. Cool/Warm Mist Control Button
  5. Mist Output Setting Button

Timer Mode
4, 8, 12 hour auto shut off. Feature will allow the unit to run for the preset time and then shut off after the time has lapsed or if it runs out of water.
Tank Refill Indicator
Once the tank is empty, the Refill indicator will illuminate, the unit will stop working, all buttons will not function until you refill the tank.
For refill, please unplug the unit and empty any residual water from the base and the tank (follow the Daily Maintenance Instructions). Then follow the Filling Instructions to refill the tank and put back into the humidifier to begin operation.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

Daily Maintenance:

  1. Be sure the unit is OFF and is disconnected from the electrical outlet.
  2. Remove the tank from the humidifier and place in sink or tub.
  3. Remove the tank cap and empty excess water from tank.
  4. Refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill.
  5. Follow Operating Instructions to turn on the humidifier.
    NOTE: Before operation of the humidifier, ensure the rubber valve is in place to cover the hole at the bottom of the base.

Weekly Maintenance:

  1. Repeat previous steps in Daily Maintenance.
  2. Pour 1 cup (8 oz) of undiluted white vinegar in the water inlet area. The vinegar will automatically transfer to the transducer and float area. Clean the base by partially filling the base with 1 cup (8 oz) of undiluted white vinegar. Leave this solution in the base for 20 minutes, while cleaning all the interior surfaces with the blue soft brush that is nested on the bottom of the tank. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar after the soaking cycle is complete, pour vinegar out (pour towards back left corner of base as indicated by the arrow on the base. Be careful not to get it in the fan housing.
  3. Rinse with clean warm water to remove the cleaning solution before disinfecting the tank.
  4. To rinse, pour 1 cup of cool tap water in the air inlet area. Allow to reach transducer area. Pour out water.

To Disinfect Humidifier Base and Tank:

  1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach.
  2. Return tank to base. Allow to set for 20 minutes. Use clean water in tank to flush system. Do not allow water to get in the fan housing.
  3. Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel.
  4. Discard bleach water in the base, pour towards the left corner of base.
  5. To clean the humidifier base, pour out all excess water. Rinse thoroughly to remove any sediment to dirt. Wipe clean and dry with a clean cloth or paper towel. Do not use metal cleaning utensils of abrasive cleansers.
    NOTE: Do not scrape the transducer with any other object other than the brush provided. Damage could occur and cause malfunction.

STORAGE INSTRUCTIONS
When not using your humidifier for an extended period of time:

  1. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
  2. Place the humidifier in the original carton and store in a cool, dry place.

REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of the following:

  • Visit your local retailer
  • Go to www.bionaire.com
  • Call Consumer Service at 1-800-253-2764

TROUBLESHOOTING

TROUBLESHOOTING
Trouble Probable Cause Solution

Water Leaks from Tank.

Tank/cap gasket is missing.
Unit tilted or not leveled.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or reposition gasket.
Place unit it on a flat or leveled surface.
Tighten the cap.
Fill with cool water only.

Crack in Tank.

Hot water will cause tank to pressurize.
Tanks will crack if hit or dropped.
Fill with cool water only.
Handle tank with care. If there is crack on tank, replace with a new tank.

Film on Tank.

Mineral deposits. Clean/disinfect tank as instructed in weekly cleaning instructions.

Mist output minimal to none.

Scale build up on transducer. Replace the demineralization cartridge by following the maintenance instructions.

Reduced or no mist.

Out of water.
Humidistat set too low.
No humidistat on this unit.
Fill tank.
Increase setting to High.
Properly seat the demineralization cartridge and reseat tank.

If you have any questions regarding your product or would like to learn more about other Bionaire® products, please contact our Consumer Service Department at 1-800-253-2764 or visit our website at www.bionaire.com.

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS
Question Answer

What are the variables that affect run time?

The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room where the humidifier is placed.
Home furnishings in the room where the humidifier is placed.

How do I remove film on water tank?

Vinegar and water soak will remove it within 20 mins.

How can I extend the run time?

Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time.

© 2016 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All rights reserved. Imported and distributed by Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions, 20B Hereford Street, Brampton, Ontario L6Y 0M1.

Questions? Comments? Call 1-800-253-2764 in North America.

Videos

Bionaire BUL9500 U Humidifier in 4k UHD Video

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Bionaire BUL9500 Series - Warm Or Cool Ultrasonic Humidifier Manual

Advertisement

Need Assistance?

Do you have a question about the BUL9500 Series that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents