Advertisement
IMPORTANT NOTES: Please read this entire manual carefully before using this device. Product may vary from picture.
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.
Do not attempt to modify this plug or defeat this safety feature in any way.
NOTE: This is an electrical appliance and requires attention when in use.
NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.
The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating information placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.
STRANGULATION HAZARD. Keep cord out of children's reach. NEVER place humidifier or cords within 3 feet of crib or playing area.
An ultrasonic transducer atomizes water, producing refreshing visible cool or warm mist.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40% - 50%.
NOTE: The display range is 30% - 90%, If your room humidity level falls below 30%, the unit will still display 30. If your room humidity level rises above 90%, the unit will continue to display 90.
Press the Warm/Cool Mist Button (G) to switch between Cool Mist and Warm Mist mode. The corresponding icon (() for Warm / () for Cool Mist) will illuminate on LCD display (B) to indicate which mode is activated. Cool Mist and Warm Mist can operate at all speed settings. Press the Speed Button (I) to switch between High (2) and Low (1) settings.
NOTE: For optimal warm mist output allow up to 20 minutes of run time after selecting the warm mist function.
The humidifier is designed with 5 comfort modes; you may select the one which suits your need. Press the Comfort Select Button (F) to activate the function, and then turn the Dial Knob (J) to cycle through the 5 comfort levels and select your preferred mode; the selected mode will illuminate on LCD display (H):
Your humidifier is equipped with a digital humidistat that allows you to set your humidifier to your desired comfort level. To preset a precise comfort level, turn the Dial Knob (J) to adjust the humidity level ranging from 35% to 60% or "Stay On" setting for constant humidity. The LCD Display (H) will show the selected humidity level for 5 seconds and then change back to show the room humidity. When the room humidity level rises above the set humidity, the humidifier will stop. When the room humidity level drops below the set humidity, the humidifier will turn on automatically to maintain the preset humidity level.
NOTE: To shut the humidifier off at any setting, press the Power Button (K). The humidistat has memory. This means that when you turn the unit back on, it will be at the last humidity setting before the humidifier is turned off. However, if the humidifier is unplugged, the digital humidistat will no longer remember the previous humidity setting. You will need to reset the digital humidistat if the humidifier is unplugged.
DO NOT move the humidifier with water in the tank (C) or the humidifier base (E). The moving action of the water may activate the water tank's release nozzle and overfill the humidifier base. This may cause the humidifier to function intermittently, or stop emitting mist. Should his occur, simply remove the excess water from the humidifier base.
NOTES:
Once the tank (C) is empty, TANK EMPTY will illuminate in the LCD display (H), and the humidifier will shut off automatically. Unplug the humidifier from the electrical outlet. Before refilling, empty any residual water from the base (E) and the tank (follow the Daily Maintenance Instructions.)
Your humidifier is equipped with a 24-Hour Auto Shut-off Timer feature. This allows you to program your humidifier to shut off automatically after running for a defined time interval.
The following maintenance procedures must be routinely followed in order to ensure proper efficient operation of your humidifier. The unit will not work properly if not cleaned regularly.
When the unit is in use, daily and weekly maintenance is recommended. Regular weekly cleaning prevents scale buildup on the heating element and tray. It also prevents micro-organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and to the avoidance of algae or bacteria buildup.
If your humidifier will not be in use for two days or more, follow these instructions:
Trouble | Probable Cause | Solution |
Water leaks from tank | Tank rubber ring is missing Cap is not tight enough Tank water is hot | Remove tank cap and replace or reposition ring Tighten the cap Fill with cool, fresh tap water only |
Crack in tank | Hot water will cause tank to pressurize Tanks will crack if hit or dropped | Fill with cool water only Handle tank with care |
Film on tank | Mineral deposits | Clean/disinfect tank as instructed in Weekly Cleaning instructions |
Warm mist minimal to none | Heating can take up to 20 minutes to warm | Allow up to 20 minutes of run time after selecting the warm mist option |
Reduced or no mist | Scale build up on transducer | Clean transducer (refer to the Cleaning and Maintenance Instructions) |
Question | Answer |
What are the variables that affect run time? | The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:
|
How do I remove film on water tank? | See Daily Maintenance instructions. Regular cleaning is recommended. |
How can I extend the run time? | Run your unit on the lowest setting. Fill the tank all the way full, place it on the base. Let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. |
This apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. This Class B digital apparatus complies with Canadian ICES-001.
Potential for Radio/Television interference.
This device complies with part 18 of the FCC Rules. Operation is subject to the following two conditions:
This product has been tested and found to comply with the limits for a class B digital device, pursuant to Part 18 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on or off, the user is encouraged to try to correct the interference by one or more of the following measures:
NUK USA LLC warrants that for a period of three years from the date of purchase, this product will be free from defects in material and workmanship. NUK USA LLC will replace this product or any component of the product found to be defective during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. DO NOT attempt to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable.
Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. Dealers, service centers, or retail stores selling NUK USA LLC products do not have the right to alter, modify or in any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than NUK USA LLC. Further, the warranty does not cover acts of God, such as fire, flood, hurricanes and tornadoes.
NUK USA LLC shall not be liable for any incidental or consequential damages caused by the breach of any express, implied or statutory warranty or condition.
Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty.
NUK USA LLC disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise.
NUK USA LLC shall not be liable for any damages of any kind resulting from the purchase use or misuse of, or inability to use the product including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or otherwise, or for any claim brought against purchaser by any other party.
Some provinces, states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from province to province, state to state, or jurisdiction to jurisdiction.
If you have any questions regarding this warranty or would like to obtain warranty service, please call the NUK® Customer Service Center at 1-800-447-0167.
To make a claim or troubleshoot a problem, please contact the NUK® Customer Service Center at 1-800-447-0167. NUK® Customer Service will provide the assistance in resolving the issue through troubleshooting and/or provide an address for returning the product.
In the U.S.A., this warranty is offered by NUK USA LLC located in Reedsburg, Wisconsin 53959. If you have any other problem or claim in connection with this product, please visit our website: www.NUK-USA.com or call our Customer Service: (1-800-447-0167).
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
For more information on NUK® products, visit our website: www.NUK-USA.com or call NUK® Customer Service: (1-800-447-0167)
Distributed by NUK USA LLC, a subsidiary of Jarden Corporation (NYSE:JAH), 728 Booster Blvd., Reedsburg, WI 53959 USA. NUK is a registered trademark of Mapa GmbH, Zeven, Germany. Bionaire Logo is a registered trademark of Sunbeam Products, Inc. used under license. ©2013. All rights reserved. Due to continuing product development, the product inside the packaging may look slightly different than the one on the package.
03-U-C-78103 RevA
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Bionaire NUK 78102 - Ultrasonic Warm & Cool Mist Humidifier Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the NUK 78102 that isn't answered in the manual? Leave your question here.