Mobile Home Installation - England's Stove Works 50-SHW08 Installation & Operation Manual

Hide thumbs Also See for 50-SHW08:
Table of Contents

Advertisement

 
THE STRUCTURAL INTEGRITY OF THE 
MANUFACTURED HOME FLOOR, WALL AND 
CEILING/ROOF MUST BE MAINTAINED.
Mobile Home Installation (U.S. ONLY, NOT APPROVED FOR CANADIAN MOBILE HOME INSTALLATION) 
 
The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holes 
provided in the bottom of the unit for this 
purpose. Outdoor‐aired space heaters 
must be attached to the structure. Use a 
#8 copper wire to ground stove to frame 
of mobile home. 
 
The wood stove must be connected to the 
chimney system with double wall chimney 
connector which is UL listed for use in 
mobile and manufactured homes. 
 
Carefully follow all clearances listed in the 
appropriate section of this manual AND follow 
the venting manufacturer's minimum 
clearance requirements.  Similarly, be certain 
the venting system used is approved for mobile 
home use. 
 
Installation must be in accordance with 
Manufacturers Home & Safety Standard 
(HUD) CFR 3280, Part 24 as well as any applicable local codes. 
Outside Combustion Air 
The use of outside combustion air is mandatory when installing this wood stove in a mobile or 
manufactured home. 
 
The outside air connection pipe protrudes from the bottom center of the stove; a kit is available 
from England's Stove Works, Inc. designed for connecting this unit to outside combustion air. [Part 
No. AC‐OAK3] 
 
If it is not feasible to use the AC‐OAK3 outside air hookup kit in your stove installation, other 
materials may be used, provided the following rules are followed: 
o The pipe used for outside air hookup must be metal, with a minimum thickness of .0209in. 
(25 gauge mild steel) or greater and an inside diameter of approximately 2.75 in. 
o Keep pipe runs short and use a mechanical fastener at each pipe joint. 
o A screen or other protection device must be fitted over the outside air termination point to 
prevent rain, debris and nuisance animals from entering the piping system.  Inspect the 
outside combustion air inlet for block and debris monthly. 
DO NOT INSTALL IN A SLEEPING ROOM.
CAUTION 
INSTALLATION 
WARNING 
NEVER draw outside combustion air from: 
enclosed space such as an attic, garage or crawl 
 
Chimney Cap/Spark Arrestor 
 
 
Class A Chimney System 
 
 
Roof Flashing and Storm Collar 
 
 
Joist Shield/Firestop 
 
 
Mobile Home Approved Double 
Wall Chimney Connector 
 
Use silicone to create a vapor 
barrier where the chimney passes 
through to exterior. 
Caution  
Wall, floor or ceiling cavity or 
space.
Page | 15