Connector
Pin
YC101
1
Connected to
the AC inlet
2
YC102
1
Connected to
the Fuser
2
heater
YC103
1
Connected to
2
the high volt-
3
age PWB
4
5
6
7
8
9
10
11
12
YC104
1
Connected to
2
the left cool-
ing fan motor
YC105
1
Connected to
2
the fuser
3
thermistor
YC106
1
Connected to
2
the scanner
3
PWB
Service Manual
Signal
I/O
NEUTRAL
I
LIVE
I
LIVE
O
NEUTRAL
O
+24V1
O
SGND
-
FAN
I
THERM
O
+3.3V1
I
HEATN
I
SLEEP
I
ZCROSS
O
+24V2
O
+24V2
O
PGND
-
PGND
-
+24V1
O
FAN
O
+3.3V1
O
N.C.
-
THERM
I
+24V1
O
N.C.
-
GND
-
Voltage
220 - 240 V AC
AC power input
220 - 240 V AC
AC power input
220 - 240 V AC
Fuser heater output
220 - 240 V AC
Fuser heater output
24 V DC
24 V DC power source
-
Ground
0/24 V DC
Left cooling fan motor: On/Off
Analog
Fuser thermistor detection voltage
3.3 V DC
3.3 V DC power source
0/3.3 V DC
Fuser heater: On/Off
0/3.3 V DC
Sleep mode signal: On/Off
0/3.3 V DC (pulse) Zero cross signal
24 V DC
24 V DC power source (via interlock
switch)
24 V DC
24 V DC power source (via interlock
switch)
-
Ground
-
Ground
24 V DC
24 V DC power source
0/24 V DC
Left cooling fan motor: On/Off
3.3 V DC
3.3 V DC power source
-
Not used
Analog
Fuser thermistor detection voltage
24 V DC
24 V DC power source
-
Not used
-
Ground
2-3-2