Olivetti d-Copia 3003MF Service Manual page 107

Multifuction digital copier
Table of Contents

Advertisement

Code
6000
Broken Fuser heater wire
The fuser temperature does not rise
after the Fuser heater has been
turned on.
6020
Abnormally high fuser thermistor
temperature
Fuser thermistor detects abnormally
temperature.
6030
Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D
value).
Service Manual
Contents
Causes
Poor contact in
Reinsert the connector (See page 1-5-
the fuser therm-
32).
istor connector
terminals.
Poor contact in
Reinsert the connector (See page 1-5-
the Fuser heater
32).
connector termi-
nals.
Fuser thermistor
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Fuser thermal
Replace the fuser unit (See page 1-5-
cutout triggered.
32).
Fuser heater
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Broken Fuser
Replace the fuser unit (See page 1-5-
heater wire.
32).
Shorted fuser
Replace the fuser unit (See page 1-5-
thermistor.
32).
Defective control
Replace the control PWB (See page 1-
PWB.
5-37).
Poor contact in
Reinsert the connector (See page 1-5-
the fuser therm-
32).
istor connector
terminals.
Broken fuser
Replace the fuser unit (See page 1-5-
thermistor wire.
32).
Fuser thermistor
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Fuser thermal
Replace the fuser unit (See page 1-5-
cutout triggered.
32).
Fuser heater
Replace the fuser unit (See page 1-5-
installed incor-
32).
rectly.
Broken Fuser
Replace the fuser unit (See page 1-5-
heater wire.
32).
1-4-10
2MH/2MJ/2MK/2ML
Remarks
Check procedures
/corrective measures
Y113860-1

Advertisement

Table of Contents
loading

Table of Contents