Properties
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*) Depending on the cable used:
● If you are using at least OM1 fibers (attenuation ≤ 1.5 dB/km, bandwidth length product ≥
500 MHz*km), you can reach a cable length of up to 3 km.
● When are using fibers with attenuation values ≤ 1 dB/km, you can reach a cable length of
up to 5 km.
You can find additional information in the "Industrial Ethernet / PROFINET Passive network
components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
8.3

SCALANCE X108

Table 8-3
Technical specifications of the SCALANCE X108
Technical specifications
Order number
SCALANCE X108
Connection to Industrial Ethernet
Number
Design
Properties
Transmission speed
Permitted cable lengths (Industrial
Ethernet)
0 to 55 m
0 to 85 m
0 to 100 m
Electrical data
SCALANCE X-100
Operating Instructions, 02/2019, A2B00060666-10
1300 nm
At 50 µm fiber core diameter
)
At 62.5 µm fiber core diameter
Minimum
Maximum
Sensitivity min.
Input power max.
6GK5108‑0BA00‑2AA3
8
RJ-45 jacks with MDI‑X pinning
Half / full duplex
10/100 Mbps
Alternative combinations per length range
● Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180
● Max. 45 m IE TP Torsion Cable with IE FC RJ45 + 10 m TP Cord via
IE FC RJ45 Outlet
● Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180
● Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet
● Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180
● Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet
Technical specifications
8.3 SCALANCE X108
3 km
3 km
At 50 μm
-23 dBm
At 62.5 μm
-19 dBm
-14 dBm
-32 dBm
-3 dBm