5. MECHANICAL ADJUSTMENT
5.
MECHANICAL ADJUSTMENT
5.1
Adjusting the paper reference position
NOTE
• Make this adjustment after any of the following procedures has been performed.
When the PH unit has been replaced.
When the image on the print is offset in the main scan direction.
When adjustment in the following screen does not resolve a problem.
[Service Mode] - [Machine] - [Printer Area] - [Centering].
[1]
30
A
4348fs3509c0
[1]
[2]
A0XWF3C500DA
A0XWF3C501DA
Service Manual
Field Service Ver. 1.0 Jul. 2009
1. Measure the width of printed refer-
ence line A.
Specification: 3.0 mm
2. Press the drawer release button [1]
and then slide out the drawer [2]
from the paper feed cabinet.
3. Remove the right door [1].
±
1.0 mm
Y111260-5