The solar panel is an energy saving feature, which is an environmentally friendly way to provide additional power to the main unit and prolongs battery life. However, it cannot replace battery power entirely.
LOCATION | MEANING |
Clock | Main unit batteries low |
Outdoor temperature | Sensor batteries low |
The main unit can collect data from up to 3 sensors.
To set up the sensor:
TIP
Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading.
NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
To search for a sensor:
Press and hold + MODE.
The sensor reception icon in the remote sensor area shows the status:
ICON | DESCRIPTION |
Main unit is searching for sensor(s). | |
A channel has been found. | |
The sensor cannot be found. |
TIP
The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.
This product is designed to synchronize its clock automatically with a clock signal.
RMR803:
Slide EU / UK to select the signal received.
RMR803A:
To enable / disable signal reception:
Press and hold to enable or to disable signal reception.
NOTE
Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal reception is unsuccessful, place your unit next to a window, press and hold to force another signal search.
Clock signal reception indicator:
STRONG SIGNAL | WEAK / NO SIGNAL |
To set the clock manually, disable the signal reception first.
RMR803: Time zone offset sets the clock +/- 23 hours from the received clock signal time.
RMR803A: Select the time zone: (P) Pacific, (E) Eastern, (C) Central or (M) Mountain.
NOTE
The language options are English (E), German (D), French (F), Italian (I), Spanish (S) and Russian (R).
To select display mode:
Press MODE to choose between clock with seconds, clock with weekday or calendar.
To toggle temperature unit:
Press °C / °F.
To toggle between each outdoor sensor's readings:
Press repeatedly.
OR
Press and hold + MEM for 2 seconds to initiate auto toggle of outdoor channels.
To end press .
To toggle between current, minimum and maximum records:
Press MEM repeatedly.
To clear the records:
Press and hold MEM.
If the sensor falls between 3°C to -2°C (37°F to 28°F), the green LED indicator will flash, and will stop flashing once the temperature is out of this range.
NOTE
As ice alert is only applicable to channel 1, to prevent flashing of LED, select channel 2 or 3 on outdoor sensor.
Press LIGHT to activate backlight for 5 seconds.
Press RESET to return to the default settings.
NOTE
The technical specifications for this product and the contents of the user manual are subject to change without notice.
NOTE
Features and accessories will not be available in all countries. For more information, please contact your local retailer.
TYPE | DESCRIPTION |
MAIN UNIT | |
L x W x H | 73 x 38 x 132 mm (2.87 x 1.50 x 5.20 in) |
Weight | 170 g (6 oz) without battery |
Temperature range | -5°C to 50°C (23°F to 122°F) |
Signal frequency | 433 MHz |
Indoor humidity range | 25% - 95% |
Power | 2 x UM-3 (AA) 1.5 V batteries |
REMOTE UNIT (THN132N) | |
L x W x H | 96 x 50 x 22 mm (3.78 x 1.97 x 0.87 in) |
Weight | 62 g (2.22 ounces) |
Transmission range | 30 m (98 ft) unobstructed |
Temperature range | -20°C to 60°C (-4°F to 140°F) |
Power | 1 x UM-3 (AA) 1.5 V batteries |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Oregon Scientific RMR803A, RMR803 - Thermometer-Hygrometer-Atomic Clock Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the RMR803A that isn't answered in the manual? Leave your question here.