Oregon Scientific RMR232PHU User Manual
Oregon Scientific RMR232PHU User Manual

Oregon Scientific RMR232PHU User Manual

Digital in-out thermometer with rf clock & photo frame

Advertisement

Digital In-Out Thermometer
with RF Clock & Photo Frame
MODEL: RMR232PHN/RMR232PHU (UK Version)
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the RMR232PHN/
RMR232PHU, an In-Out Thermometer with Radio-Controlled Clock
and a Photo Frame attached.
The basic package comes with the following:
-- Main unit (RMR232PHN/RMR232PHU).
-- Remote thermo sensor unit
-- Blue and metallic grey exchangeable front key panels.
The main unit shows the indoor temperature, calendar clock and
temperatures collected and transmitted by the remote unit.
The main unit is also capable of keeping track of the maximum and
minimum temperature measured. No wire installation is required
and the RMR232PHN/RMR232PHU operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within an
approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77). (MSF 60 for UK Version)
You can also set the calendar clock manually when it is off range.
Other features include five-language display and two-minute
crescendo daily alarm.
MAIN FEATURES: MAIN UNIT
K
I
N L M
1
A
B
C
D
E
F
G
H
P
J
O
O

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific RMR232PHU

  • Page 1 MODEL: RMR232PHN/RMR232PHU (UK Version) USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR232PHN/ RMR232PHU, an In-Out Thermometer with Radio-Controlled Clock and a Photo Frame attached. The basic package comes with the following: -- Main unit (RMR232PHN/RMR232PHU). -- Remote thermo sensor unit -- Blue and metallic grey exchangeable front key panels.
  • Page 2 THREE-LINE DISPLAY Facilitates easy reading of remote and indoor temperatures and calendar clock RADIO RECEPTION SIGNAL Indicates the condition of radio reception MEMORY [MEM] BUTTON Recalls the maximum or minmum temperature of main and remote unit UP [ ] BUTTON Advances the value of a setting [ MODE/SET ] BUTTON Toggles the display modes and confirms entry while setting...
  • Page 3: Before You Begin

    LED INDICATOR Flashes when the remote unit transmits a reading BATTERY COMPARTMENT Accommodates two UM-3 or AA-size 1.5V batteries BATTERY DOOR WALL-MOUNT RECESSED HOLE Supports the remote until in wall-mounting BEFORE YOU BEGIN For best operation, 1. Insert batteries for remote units before doing so for the main unit.
  • Page 4: Low Battery Warning

    2. Install 2 alkaline batteries (MU-3 or “AA” size 1.5 V) strictly according to the polarities shown. 3. Replace the battery compartment door and secure its screws. LOW BATTERY WARNING When it is time to replace batteries, the respective low-battery indicator will show up on the indoor or outdoor temperature display.
  • Page 5: Wall Mounting

    COMPATIBLE PHOTO SIZES Three different standard sizes of photo can be placed in the photo frame: 8 x12 cm (3.15” x 4.72” ) 9 x13 cm (3.54” x 5.12” ) 10 x15 cm (3.94” x 5.9” ) HOW TO USE THE TABLE STAND WALL MOUNTING The main unit has a table stand which can support the unit on a flat surface.
  • Page 6: The Reset Button

    THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. GETTING STARTED Once batteries are in place for the remote unit, they will start transmitting temperature readings at 78-second intervals.
  • Page 7: Maximum And Minimum Temperatures

    The unit is in searching mode. Temperature readings securely registered. No signals. MAXIMUM AND MINIMUM TEMPERATURES The maximum and minimum recorded indoor and outdoor temperatures will be automatically stored in memory. To display them, press [ MEM ] once to display the maximum temperature and again the minimum temperature.
  • Page 8: About Radio Reception

    Frankfurt DCF77 radio signal.(MSF for UK Version) When the RMR232PHN/RMR232PHU is within range, its radio- control mechanism will override all manual settings unless auto- reception of radio signal has been deactivated.
  • Page 9: How To Stop An Alarm

    HOW TO SET THE CALENDAR CLOCK MANUALLY To set the clock manually, hold [ MODE/SET ] for two seconds in clock display mode. The 12-hr or 24-hr display will blink. Use ] or [ ] to select 12 hour or 24 hour format. Press [ MODE/SET ] to confirm.
  • Page 10: Specifications

    PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Do not immerse the unit in water. 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit.
  • Page 11: Ec Declaration Of Conformity

    Main unit : 350g (without battery) Remote sensing unit : 46g (without battery) Dimension Main unit : 180(L) x 178(W) x 28(T) Remote sensing unit : 89(L) x 44(W) x 21(T) EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 03 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied:...