Multi-Channel IN-OUT Thermometer
with Cable Free Sensor and RF Clock
MODEL: RMR132
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the RMR132 Multi-Channel
In-Out Thermometer with 433MHz cable free sensor and
radio-controlled calendar clock.
The basic package comes with a main unit, which is the
temperature and calendar clock station, and a remote unit, the
thermo sensor.
The main unit has large read-outs for indoors temperature,
calendar clock and temperatures collected and transmitted by the
remote unit. The main unit can support up to three remote units.
The main unit is capable of keeping track of the maximum and
minimum temperature of different sites. And no wire installation
is required and the RMR132 operates at 433MHz.
As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within an
approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77).
You can also set the calendar clock manually when it is off range.
Other features include four-language display, four-step crescendo
dual alarms and interchangeable display modes.
MAIN FEATURES
A
B
C
D
E
H
R
L
AL
K
ON / OFF
O
P
1
MAX
CHANNEL
MAX
ZONE
CHANNEL
MEMORY
SET / MODE
24 hr
OFF /
C
F
M
N
Q
F
J
G
I

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific RMR132

  • Page 1 Cable Free Sensor and RF Clock MODEL: RMR132 USER'S MANUAL CHANNEL INTRODUCTION Congratulations on your purchase of the RMR132 Multi-Channel ZONE In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock. CHANNEL The basic package comes with a main unit, which is the...
  • Page 2 K. [ L ] BUTTON A. THREE-LINE LCD DISPLAY Facilitates easy reading of remote and indoors temperatures Advances the value of a setting and calendar clock L. [ M ] BUTTON B. [ ] BATTERY-LOW INDICATOR Decreases the value of a setting (REMOTE SENSOR) °...
  • Page 3: Before You Begin

    A. LED INDICATOR MAIN FEATURES: REMOTE UNIT Flashes when the remote unit transmits a reading B. CHANNEL SLIDE SWITCH Designates the remote unit Channel 1, Channel 2 or Channel 3 C. RESET BUTTON Returns all settings to default values D. BATTERY COMPARTMENT Accommodates two AAA-size batteries E.
  • Page 4: Low Battery Warning

    Note that the effective range is vastly affected by the building BATTERY INSTALLATION: MAIN UNIT materials and where the main and remote units are positioned. Try various set-ups for best result. 1. Gently lift the tab on the battery compartment door. Though the remote units are weather proof, they should be placed 2.
  • Page 5: How To Use The Table Stand

    Remote unit HOW TO USE THE TABLE STAND Wall-mount Table Stand OR WALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the unit on a wall using the recessed screw hole. As for the remote unit, it comes with a wall-mount holder and a removable stand.
  • Page 6 If no readings are received from one particular channel for more than two minutes, blanks “---” will be displayed until further readings are successfully searched. Check the remote unit is sound and secure. You can wait for a little while or press [CHANNEL] CHANNEL and [MEMORY] simultaneously to enforce an immediate search.
  • Page 7: Maximum And Minimum Temperatures

    MAXIMUM AND MINIMUM TRANSMISSION COLLISION TEMPERATURES Signals from other household devices, such as door bells, home security systems and entry controls, may interfere with those of The maximum and minimum recorded indoor temperatures and this product and cause temporarily reception failure. This is normal those of each channel will be automatically stored in memory.
  • Page 8: About Radio Reception

    MODE 4. Second Time-Zone CALENDAR CLOCK DISPLAY MODES Hour, Minute Day-of-the-Week The RMR132 supports four display modes in the sequence of: Day, Month MODE 1. Local Time Hour, Minute Second Day, Month Each press on the [SET/MODE] button will toggle the display in the above order.
  • Page 9: To Set Alarm

    - No Reception through Sunday. For the second time zone, which is indicated by the ZONE ICON, enter the hour offset using the[L] or [M]buttons and the RMR132 - Receiving will calculate the second time accordingly. If there is an item you do not wish to change, simply press [SET/MODE] to bypass the item.
  • Page 10: How To Stop An Alarm

    3. Do not subject the unit to excessive: force, shock, dust, 4. Press [24 hr OFF / ((•))]. The minute digits will blink. temperature, or humidity. Such treatment may result in 5. Enter the minutes using [L] or [M]. malfunction, a shorter electronic life span, damaged batteries, 6.
  • Page 11: Specifications

    Radio Controlled Clock SPECIFICATIONS Maintime set and synchronized by Radio Signal DCF77 for Continental/ Central Europe Temperature Measurement 24 h display with hh : mm ss Main unit Date Format : Day. Month. Indoor Temperature measurement Day of week selectable in 4 language (E, D, F, I) Proposed operating range : -5.0°C to +50.0°C (23.0°F to 122.0°F)
  • Page 12: Ec Declaration Of Conformity

    This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R&TTE © 2003 Oregon Scientific. All rights reserved. 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Efficient use of radio frequency spectrum (Article 3.2 of the R&TTE Directive)