  1. LCD digital thermometer display range in °C.
  2. Indoor / outdoor temperature measurement.
  3. Simultaneously displays indoor and outdoor temperature.
  4. Temperature measuring range:
    INDOOR -5°C to 50°C (23°F to 122°F)
    OUTDOOR -40°C to 50°C (-40°F to 122°F).
  5. Resolution (indoor / outdoor): 0.1°C (0.1°F).
  6. Maximum and minimum temperature memory function.
  7. Built-in plastic table stand.
  8. Large, easy-to-read display.

INDOOR / OUTDOOR TEMPERATURE MEASUREMENT

  1. This thermometer can simultaneously measure the temperature inside the house as well as outside.
  2. Place the external sensor probe outside the window.

TO VIEW MAXIMUM AND MINIMUM TEMPERATURE

  1. Press MEM once and the "MEM" symbol will show on the display.
  2. Press MIN once and the minimum indoor and outdoor reading will appear together with the flashing "MIN" symbol.
  3. Press MAX once and the maximum indoor and outdoor reading will appear together with the flashing "MAX" symbol.
  4. Press MEM again and the display will resume to the current temperature reading.

TO CLEAR MAXIMUM AND MINIMUM TEMPERATURE MEMORY

  1. Press and hold MIN, press MEM at the same time to clear minimum temperature memory.
  2. Press and hold MAX, press MEM at the same time to clear maximum temperature memory.

USE OF PLASTIC STAND

Flip out the plastic stand at the back of the unit to use the table stand.

REPLACEMENT OF BATTERY

Slide the battery cover open. Remove the old battery and insert 1 new UM-3 (AA) 1.5V battery. Make sure that the polarities (+ and -) match the indication shown inside the battery compartment. Replace the battery cover.

PRECAUTIONS

This unit is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions:

  • Placement of this product on wood surfaces with certain types of finishes, such as clear varnish, may result in damage to the finish. Consult the furniture manufacturer's care instructions for direction as to the types of objects that may safely be placed on the wood surface. Oregon Scientific shall not be responsible for any damage to wood surfaces from contact with this product.
  • Do not cover the ventilation holes. Make sure items that are nearby such as newspapers, tablecloths, curtains etc cannot accidentally cover the ventilation holes.
  • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
  • Do not clean the unit with abrasive or corrosive materials. This may scratch the plastic parts and corrode the electronic circuit.
  • Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.
  • This product may malfunction if electrostatic discharge or radio interference appears in the environment and / or affects the ac power line. The unit will revert to normal operation when interference stops.
  • Do not tamper with the unit's internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.
  • Only use fresh batteries as specified in the user's instructions. Do not mix new and old batteries as the old ones may leak.
  • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • Due to printing limitations, the displays shown in this manual may differ from the actual display.
  • The contents of this manual may not be reproduced without the permission of the manufacturer.

NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads.

We hope you will find all the information you need on our website, however if you're in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp

EU-DECLARATION OF CONFORMITY

Hereby, Oregon Scientific, declares that this Indoor / Outdoor Thermometer with Memory (NTA880) is in compliance with EMC directive 89/336/CE. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Oregon Scientific NTA880 - Indoor/Outdoor Thermometer With Memory Manual

Advertisement

Need Assistance?

Do you have a question about the NTA880 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents